During power-up, VDD
must always start and settle before VOFFSET plus tDELAY1
specified in Power Supply Sequence Requirements, VBIAS, and
VRESET voltages are applied to the DMD.
During power-up, it is a strict
requirement that the voltage difference between VBIAS and
VOFFSET must be within the specified limit shown in
Recommended Operating Conditions.
During power-up, there is no
requirement for the relative timing of VRESET with respect to
VBIAS.
Power supply slew rates during
power-up are flexible, provided that the transient voltage levels follow the
requirements specified in Absolute Maximum Ratings, in Recommended
Operating Conditions, and in Power Supply Sequence
Requirements.
During power-up, LVCMOS input
pins must not be driven high until after VDD has settled at operating
voltage listed in Recommended Operating Conditions.