TIDT366 November 2023
Overcurrent protection (OCP) was performed at the electrical load side, Table 3-2 shows OCP at different input voltage.
| Parameter | 300 VIN | 600 VIN | 1000 VIN |
|---|---|---|---|
| OCP (A) | 4.307 | 4.338 | 4.417 |
Figure 3-50 OCP at 300
VIN
Figure 3-52 OCP at 1000
VIN
Figure 3-51 OCP at 600
VIN