SNOK006 April 2024 TPS7H6013-SP
HDR devices were stressed up to 100krad(Si) for biased and unbiased conditions.
| Total Samples: 11 units + 1 control | ||
|---|---|---|
| Exposure Levels: | ||
| 10krad(Si) | 50krad(Si) | 100krad(Si) |
| 182, 202, 204 | 259, 346, 347 | 354, 363, 366, 383, 417 |
| Total Samples: 11 units + 1 control | ||
|---|---|---|
| Exposure Levels: | ||
| 10krad(Si) | 50krad(Si) | 100krad(Si) |
| 418, 419, 443 | 462, 478, 503 | 513, 526, 532, 533, 534 |