SLVUDR9 February   2026

 

  1.   1
  2. 1Description
  3.   Get Started
  4. 2Features
  5. 3Applications
  6.   6
  7. 4Evaluation Module Overview
    1. 4.1 Introduction
    2. 4.2 Kit Contents
    3. 4.3 Specification
    4. 4.4 Device Information
  8. 5Hardware
    1. 5.1 Power Requirements
    2. 5.2 Setup
    3. 5.3 Test Points
      1. 5.3.1 Analog Inputs
      2. 5.3.2 Analog Outputs
    4. 5.4 Cautions and Warnings
  9. 6Implementation Results
    1. 6.1 Evaluation Setup
    2. 6.2 Performance Data and Results
  10. 7Hardware Design Files
    1. 7.1 Schematics
    2. 7.2 PCB Layouts
    3. 7.3 Bill of Materials (BOM)
  11. 8Additional Information
    1. 8.1 Trademarks
  12. 9References

Performance Data and Results

The following figure represents the percentage error from 0A to 200A. The red trace represents the non-calibrated results. The yellow trace represents the offset calibrated results. The green trace represents the results after gain and offset calibration.

AMC-AMP-200APK-EVM Percentage ErrorFigure 6-2 Percentage Error