SBOK092 December   2024 OPA4H199-SP

 

  1.   1
  2.   2
  3.   Trademarks
  4. 1 Introduction
  5. 2 Single-Event Effects (SEE)
  6. 3 Device and Test Board Information
  7. 4 Irradiation Facility and Setup
  8. 5 Depth, Range, and LETEFF Calculation
  9. 6 Test Setup and Procedures
  10. 7 Destructive Single-Event Effects (DSEE)
    1. 7.1 Single-Event Latch-up (SEL) Results
  11. 8 Single-Event Transients (SET)
  12. 9 Event Rate Calculations
  13. 10Summary
  14.   A Total Ionizing Dose from SEE Experiments
  15.   B References

Total Ionizing Dose from SEE Experiments

The production OPA4H199-SP is rated to a total ionizing dose (TID) of 100krad(Si). In the course of the SEE testing, the heavy-ion exposures delivered approximately 10krad(Si) per 107 ions/cm2 run. The cumulative TID exposure was controlled below 100krad (Si) per unit. All six OPA4H199-SP devices used in the studies described in this report were fully-functional after the heavy-ion SEE testing was completed.