4 修订历史记录
Changes from E Revision (August 2015) to F Revision
-
Changed "operating free-air" to "junction" in Absolute Maximum Ratings table condition lineGo
-
Changed OUT pin max voltage from 7 to VIN + 0.3 V or 7 V, whichever is smaller, in Absolute Maximum Ratings table (moved OUT from first row to second row)Go
-
Deleted TA, ambient temperature range, from Recommended Operating Conditions tableGo
-
Changed COUT max value from 47 µF to 200 µF in Recommended Operating Conditions tableGo
-
Added note (2) to Recommended Operating Conditions table regarding COUT max valueGo
-
Added feedforward capacitance to Recommended Operating Conditions tableGo
-
Deleted redundant notes 2 to 7 in the Thermal Information table; all information from deleted notes available in application report shown in note (1)Go
-
Changed note (1) in Electrical Characteristics; deleted initial reference to R1 and updated R2 resistor rangeGo
-
Changed Output Capacitor (OUT) section; reworded for clarity Go
Changes from D Revision (September 2013) to E Revision
-
添加了 ESD 额定值表,特性 描述部分,器件功能模式,应用和实施部分,电源相关建议部分,布局部分,器件和文档支持部分以及机械、封装和可订购信息部分。Go
Changes from C Revision (January 2013) to D Revision
-
Added new text to Internal Current Limit sectionGo
Changes from B Revision (July 2012) to C Revision
-
Deleted maximum value for Output Current Limit parameter in Electrical Characteristics tableGo
Changes from A Revision (June 2012) to B Revision
-
Changed Output Voltage, ILIM parameter test conditions in Electrical Characteristics tableGo
Changes from * Revision (January 2012) to A Revision
-
更改了可调输出特性着重号Go
-
已更改说明部分第一段中输出电压的最小值Go
-
Changed Electrical Characteristics condition lineGo
-
Changed Output Voltage Accuracy parameter in Electrical CharacteristicsGo
-
Changed test conditions for Dropout Voltage parameter in Electrical CharacteristicsGo
-
Changed note (1) in Electrical CharacteristicsGo
-
Added new note (4) to Electrical CharacteristicsGo