SLVSK31 June 2026 TLV9023L
PRODUCTION DATA
The unique feature of the TLV9023L is the output latching capability. The output latches upon the first threshold crossing to allow capturing of an event or error condition without the full attention of a system controller. This allows events to be captured at start up while the system controller is still initializing. The system controller can reset the latch after performing any needed tasks. The output is latched at power-up and requires the CLR pin to be pulled low to clear the latch.
The three outputs of the comparators are available individually, and also ANDed together, along with the AND_IN logic input, to the push-pull AND_OUT output. The AND_IN input can be used to dasy-chain multiple TLV9023L circuits, or external comparator outputs or error logic lines.
These comparators also feature fault-tolerant inputs that can go up to 6V without damage with no output phase inversion. This makes this family of comparators designed for precision voltage monitoring in harsh, noisy environments.