over operating free-air temperature range (unless otherwise noted)(1)
|
|
MIN |
MAX |
UNIT |
| VCC |
Supply voltage(2) |
VCC+ |
0 |
+18 |
V |
| VCC– |
–18 |
0 |
V |
|
Input voltage, either input(2)(3) |
–15 |
+15 |
V |
|
Input current(4) |
–10 |
10 |
mA |
|
Duration of output short circuit(5) |
Unlimited |
| TJ |
Operating virtual-junction temperature |
|
+150 |
°C |
| Tstg |
Storage temperature range |
–60 |
+125 |
°C |
(1) Operation outside the
Absolute Maximum Ratings may cause permanent
device damage.
Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the
Section 5.3 but within the
Absolute Maximum Ratings, the device may not be fully
functional, and this may affect device reliability, functionality, performance,
and shorten the device lifetime.
(2) All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC–.
(3) The magnitude of the input voltage must never exceed the magnitude of the supply voltage.
(4) Excessive input current flows if a differential input voltage in exceeding
approximately 0.6V is applied between the inputs, unless some limiting
resistance is used.
(5) The output can be shorted to ground or either power supply. Temperature and/or
supply voltages must be limited to the maximum dissipation rating is not
exceeded.