SNVS471H January 2007 – April 2026 LM5575
PRODUCTION DATA
RT sets the oscillator switching frequency. Generally, higher frequency applications are smaller but have higher losses. Operation at 300kHz was selected for this example as a reasonable compromise for both small size and high efficiency. The value of RT for 300kHz switching frequency can be calculated as Equation 6.
The nearest standard value of 21kΩ was chosen for RT.