ZHCSG76A April 2017 – March 2025 INA233
PRODUCTION DATA
STATUS_IOUT is a standard PMBus command that returns the value of the of a number of flags related to output, current, and power. Use the PMBus read byte protocol to access this command. To clear bits in this register, clear the underlying fault and issue a CLEAR_FAULTS command or write a 1 to the bit to be cleared. Table 6-12 lists the definitions for this command.
| BIT | NAME | MEANING | DEFAULT |
|---|---|---|---|
| 7 | IOUT_OC fault | Not supported | 0 |
| 6 | IOUT_OC fault with LV shutdown | Not supported | 0 |
| 5 | IOUT_OC_WARN | An input undercurrent warning has occurred | 0 |
| 4 | IOUT_UC fault | Not supported | 0 |
| 3 | Current share fault | Not supported | 0 |
| 2 | In power-limiting mode | Not supported | 0 |
| 1 | POUT_OP fault | Not supported | 0 |
| 0 | POUT_OP_WARN | Not supported | 0 |