ZHCSH31B August 2017 – February 2018 DRV10987
PRODUCTION DATA.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| OverTemp | TempWarning | VCC_OV | VREG_OC | OverCurr | CP_UVLO | VREG_UVLO | VCC_UVLO |
| R/W1C-0 | R//W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| V3P3_UVLO | Reserved | Lock5 | Lock4 | Lock3 | Lock2 | Lock1 | Lock0 |
| R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 | R/W1C-0 |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | OverTemp | R//W1C | 0 |
Bit to indicate device temperature is over the limit. |
| 14 | TempWarning | R/W1C | 0 | Bit to indicate device temperature is over the warning limit. |
| 13 | VCC_OV | R/W1C | 0 | Bit to indicate the supply voltage is above the upper limit. |
| 12 | VREG_OC | R/W1C | 0 | Bit to indicate that the switching regulator is in an overcurrent condition. |
| 11 | OverCurr | R/W1C | 0 | Bit to indicate that an overcurrent event happened. |
| 10 | CP_UVLO | R/W1C | 0 | Bit to indicate that the charge pump is in an undervoltage fault condition. |
| 9 | VREG_UVLO | R/W1C | 0 | Bit to indicate that the switching regulator (VREG) is in an undervoltage fault condition. |
| 8 | VCC_UVLO | R/W1C | 0 | Bit to indicate that the supply (VCC) is in an undervoltage fault condition. |
| 7 | V3P3_UVLO | R/W1C | 0 | Bit to indicate that the 3.3 V LDO regulator is in an undervoltage fault condition. |
| 6 | Reserved | R/W1C | 0 | Do not access this bit. |
| 5 | Lock5 | R/W1C | 0 | Stuck in closed loop fault |
| 4 | Lock4 | R/W1C | 0 | Stuck in open loop fault |
| 3 | Lock3 | R/W1C | 0 | No motor fault |
| 2 | Lock2 | R/W1C | 0 | Kt abnormal fault |
| 1 | Lock1 | R/W1C | 0 | Speed abnormal fault |
| 0 | Lock0 | R/W1C | 0 | Hardware current-limit fault |