ZHCSWD1C December   2023  – May 2024 CD54AC240 , CD54AC244 , CD54ACT240 , CD54ACT241 , CD54ACT244 , CD74AC240 , CD74AC244 , CD74ACT240 , CD74ACT241 , CD74ACT244

PRODUCTION DATA  

  1.   1
  2. 1 特性
  3. 2 说明
  4. 3 Pin Configuration and Functions
  5. 4 Specifications
    1. 4.1 Absolute Maximum Ratings
    2. 4.2 Recommended Operating Conditions
    3. 4.3 Thermal Information
    4. 4.4 Static Electrical Characteristics: AC Series
    5. 4.5 Electrical Characteristics: ACT Series
    6. 4.6 Switching Characteristics: AC Series
    7. 4.7 Switching Characteristics: ACT Series
  6. 5 Parameter Measurement Information
  7. 6 Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Device Functional Modes
  8. 7 Application and Implementation
    1. 7.1 Power Supply Recommendations
    2. 7.2 Layout
      1. 7.2.1 Layout Guidelines
  9. 8 Device and Documentation Support
    1. 8.1 Documentation Support (Analog)
      1. 8.1.1 Related Documentation
    2. 8.2 接收文档更新通知
    3. 8.3 支持资源
    4. 8.4 Trademarks
    5. 8.5 静电放电警告
    6. 8.6 术语表
  10. 9 Revision History
  11. 10Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • N|20
  • DW|20
散热焊盘机械数据 (封装 | 引脚)
订购信息

Switching Characteristics: ACT Series

tr, tl = 3 ns, CL = 50 pF
PARAMETER CHARACTERISTICS VCC (V) AMBIENT TEMPERATURE (TA) - °C UNIT
-40 to +85 -55 to +125
MIN MAX MIN MAX
Propagation Delays: Data to Outputs
tPLH ACT240 5(2) 2.3 7.8 2.2 8.6 ns
tPHL
tPLH ACT241, 244 5 2.5 8.7 2.4 9.6 ns
tPHL
tPZL Output Enable Times 5 3.5 12.2 3.4 13.4 ns
tPZH
tPLZ Output Disable Times 5 3.5 12.2 3.4 13.4 ns
tPHZ
Power Dissipation Capacitance
CPD§(3) ACT240 — 65 Typ 65 Typ pF
ACT241, 244 — 71 Typ 71 Typ pF
Min. (Valley) Voh
VOHV(1) During Switching of Other Outputs (Output Under Test Not Switching) 5 4 Typ @25°C V
Max. (Peak) VOL
VOLP(1) During Switching of Other Outputs (Output Under Test Not Switching) 5 1 Typ. @ 25°C V
CI Input Capacitance — — 10 — 10 pF
CO 3-State Output Capacitance — — 15 — 15 pF
3.3 V: min. is @ 3.6 V; max. is @ 3 V
5 V: min. is @ 5.5 V; max. is @ 4.5 V
CPD is used to determine the dynamic power consumption, per package.
  1. For AC series: PD = VCC 2 fi (CPD + CL)
  2. For ACT series: PD = VCC 2 fi (CPD + CL) + VCC ΔlCC where fi = input frequency
    1. CL = output load capacitance
    2. VCC = supply voltage.