INA210

AKTIV

Bidirektionaler hochpräziser Strommessverstärker, 26 V

Produktdetails

Product type Analog output Common-mode voltage (max) (V) 26 Common-mode voltage (min) (V) -0.3 Input offset (±) (max) (µV) 35 Input offset drift (±) (typ) (µV/°C) 0.1 Features Bidirectional, High precision, Low-side Capable Rating Catalog Voltage gain (V/V) 200 CMRR (min) (dB) 105 Bandwidth (kHz) 14 Iq (max) (mA) 0.115 Number of channels 1 Comparators (#) 0 Gain error (%) 0.4, 0.9 Gain error drift (±) (max) (ppm/°C) 10 Slew rate (V/µs) 0.4 Operating temperature range (°C) -40 to 125
Product type Analog output Common-mode voltage (max) (V) 26 Common-mode voltage (min) (V) -0.3 Input offset (±) (max) (µV) 35 Input offset drift (±) (typ) (µV/°C) 0.1 Features Bidirectional, High precision, Low-side Capable Rating Catalog Voltage gain (V/V) 200 CMRR (min) (dB) 105 Bandwidth (kHz) 14 Iq (max) (mA) 0.115 Number of channels 1 Comparators (#) 0 Gain error (%) 0.4, 0.9 Gain error drift (±) (max) (ppm/°C) 10 Slew rate (V/µs) 0.4 Operating temperature range (°C) -40 to 125
UQFN (RSW) 10 2.52 mm² (1.8 mm × 1.4 mm) SOT-SC70 (DCK) 6 4.2 mm² (2 mm × 2.1 mm)
  • Updated format to match new TI layout and flow. Tables, figures and cross-references use a new numbering sequence throughout the document.

    Wide Common-Mode Range: –0.3 V to 26 V
  • Offset Voltage: ±35 µV (Maximum, INA210) (Enables Shunt Drops of 10-mV Full-Scale)
  • Accuracy:
    • Gain Error (Maximum Over Temperature):
      • ±0.5% (Version C)
      • ±1% (Versions A and B)
    • 0.5-µV/°C Offset Drift (Maximum)
    • 10-ppm/°C Gain Drift (Maximum)
  • Choice of Gains:
    • INA210: 200 V/V
    • INA211: 500 V/V
    • INA212: 1000 V/V
    • INA213: 50 V/V
    • INA214: 100 V/V
    • INA215: 75 V/V
  • Quiescent Current: 100 µA (Maximum)
  • SC70 and Thin UQFN Packages: All Models
  • Updated format to match new TI layout and flow. Tables, figures and cross-references use a new numbering sequence throughout the document.

    Wide Common-Mode Range: –0.3 V to 26 V
  • Offset Voltage: ±35 µV (Maximum, INA210) (Enables Shunt Drops of 10-mV Full-Scale)
  • Accuracy:
    • Gain Error (Maximum Over Temperature):
      • ±0.5% (Version C)
      • ±1% (Versions A and B)
    • 0.5-µV/°C Offset Drift (Maximum)
    • 10-ppm/°C Gain Drift (Maximum)
  • Choice of Gains:
    • INA210: 200 V/V
    • INA211: 500 V/V
    • INA212: 1000 V/V
    • INA213: 50 V/V
    • INA214: 100 V/V
    • INA215: 75 V/V
  • Quiescent Current: 100 µA (Maximum)
  • SC70 and Thin UQFN Packages: All Models

The INA21x are voltage-output, current-shunt monitors (also called current-sense amplifiers) that are commonly used for overcurrent protection, precision-current measurement for system optimization, or in closed-loop feedback circuits. This series of devices can sense drops across shunts at common-mode voltages from –0.3 V to 26 V, independent of the supply voltage. Six fixed gains are available: 50 V/V, 75 V/V, 100 V/V, 200 V/V, 500 V/V, or 1000 V/V. The low offset of the zero-drift architecture enables current sensing with maximum drops across the shunt as low as 10-mV full-scale.

These devices operate from a single 2.7-V to 26-V power supply, drawing a maximum of 100 µA of supply current. All versions are specified over the extended operating temperature range (–40°C to +125°C), and offered in SC70 and UQFN packages.

The INA21x are voltage-output, current-shunt monitors (also called current-sense amplifiers) that are commonly used for overcurrent protection, precision-current measurement for system optimization, or in closed-loop feedback circuits. This series of devices can sense drops across shunts at common-mode voltages from –0.3 V to 26 V, independent of the supply voltage. Six fixed gains are available: 50 V/V, 75 V/V, 100 V/V, 200 V/V, 500 V/V, or 1000 V/V. The low offset of the zero-drift architecture enables current sensing with maximum drops across the shunt as low as 10-mV full-scale.

These devices operate from a single 2.7-V to 26-V power supply, drawing a maximum of 100 µA of supply current. All versions are specified over the extended operating temperature range (–40°C to +125°C), and offered in SC70 and UQFN packages.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Selbe Funktionalität wie der verglichene Baustein bei gleicher Anschlussbelegung.
INA199 AKTIV Bidirektionaler Strommessverstärker, 26 V The INA199 is functionally identical with reduced accuracy at a lower price

Technische Dokumentation

Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 20
Top-Dokumentation Typ Titel Format-Optionen Neueste englische Version herunterladen Datum
* Datenblatt INA21x Voltage Output, Low- or High-Side Measurement, Bidirectional,Zero-Drift Series, Current-Shunt Monitors datasheet (Rev. K) PDF | HTML 14.11.2023
Anwendungshinweis Using a PCB Copper Trace as a Current Sense Shunt Resistor (Rev. A) PDF | HTML 27.04.2026
Anwendungshinweis Risks and Prevention of ESD, EOS, and Latch Up Events for Current Sense Amplifiers PDF | HTML 18.11.2024
Application brief Precision Current Measurements on High-Voltage Power-Supply Rails (Rev. F) PDF | HTML 17.10.2022
E-book An Engineer's Guide to Current Sensing (Rev. B) 12.04.2022
Application brief Integrating the Current Sensing Signal Path (Rev. B) PDF | HTML 29.09.2021
Application brief Integrated, Current Sensing Analog-to-Digital Converter (Rev. A) PDF | HTML 28.09.2021
Auswahlhilfe Current Sense Amplifiers (Rev. E) 20.09.2021
Circuit design Low-Drift, Low-Side, Bidirectional Current Sensing Circuit (Rev. A) PDF | HTML 02.12.2020
Technischer Artikel Why current and magnetic sensing matters for wireless earbud design PDF | HTML 11.11.2019
Application brief Precision, Low-Side Current Measurement (Rev. B) 06.03.2019
Application brief External current sense amps vs integrated onboard amplifiers for current sensing (Rev. B) 19.02.2019
Auswahlhilfe Power Management Guide 2018 (Rev. R) 25.06.2018
Anwendungshinweis Closed-Loop Analysis of Load-Induced Amplifier Stability Issues Using Zout 27.10.2017
Technischer Artikel Precise constant current regulation helps advance fast-charging PDF | HTML 15.06.2017
Application brief Low-Side Current Sense Circuit Integration 30.03.2017
Technischer Artikel How to get started with current sense amplifiers – part 4 PDF | HTML 16.07.2015
Technischer Artikel How to get started with current sense amplifiers – part 2 PDF | HTML 26.05.2015
Technischer Artikel How to get started with current sense amplifiers – part 1 PDF | HTML 19.05.2015
Weitere Dokumente Over-Current Detection Products Brochure 14.08.2014

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

INA210-215EVM — INA210-215 Evaluierungsmodul für Strom-Shunt-Monitor mit Spannungsausgang

The INA210-215 devices are voltage output, high-side measurement, bi-directional, zero-drift current shunt monitors. The INA210-215EVM is intended to provide basic functional evaluation of this device family.  The fixture layout is not intended to be a model for the target circuit, nor is it (...)

Benutzerhandbuch: PDF
Unterstützte Produkte und Hardware
Vorrätig
Limit:
??asset.out-of-stock-ti_de_DE??
Nicht verfügbar
Simulationsmodell

INA210 PSpice Model (Rev. A)

SBOM316A.ZIP (41 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA210 TINA-TI Reference Design (Rev. A)

SBOM317A.TSC (106 KB) - TINA-TI-Referenzdesign
Unterstützte Produkte und Hardware
Simulationsmodell

INA210 TINA-TI Spice Model (Rev. A)

SBOM318A.ZIP (7 KB) - TINA-TI Spice-Modell
Unterstützte Produkte und Hardware
Berechnungstool

ANALOG-ENGINEER-CALC — PC software analog engineer's calculator

Der Rechner für Analogtechniker beschleunigt viele der sich wiederholenden Berechnungen, die Entwickler von analogen Schaltungsdesigns regelmäßig durchführen müssen. Dieses PC-basierte Tool bietet eine grafische Schnittstelle mit einer Liste verschiedener gebräuchlicher Berechnungen. Das Spektrum (...)

Unterstützte Produkte und Hardware
Berechnungstool

CS-AMPLIFIER-ERROR-TOOL — Current Sense Amplifier Comparison and Error Tool

Dieser Excel-Rechner bietet einen Vergleich zwischen zwei und fünf unserer Standard-Strommessverstärker und stellt eine Tabelle mit den grundlegenden Parametern der einzelnen Bausteine bereit. Dieser Rechner nimmt außerdem die vom Benutzer gemachten Systemzustandseingaben wie Gleichtaktspannung, (...)
Unterstützte Produkte und Hardware
Referenzdesign

PMP41017 — 3-kW-Referenzdesign für zweiphasige verschachtelte Halbbrücken-LLC mit GaN und C2000-MCU™

Dieses Referenzdesign ist ein zweiphasiger 3-kW-Halbbrücken-Induktor-Induktor-Kondensator (LLC) mit den Bausteinen LMG3422 und F280039C. Dieses Design kann einen Spitzenwirkungsgrad von 98,1 % und eine Leistung von 313 W/in³; erreichen; Leistungsdichte und kann als Ausgangsstufe einer gemeinsamen (...)

Unterstützte Produkte und Hardware
Referenzdesign

TIDA-00302 — Strom-Shunt-Monitor mit transienter Robustheit – Referenzdesign

This high-side current shunt monitor is used to measure the voltage developed across a current-sensing resistor when current passes through it.

Additionally, an external protection circuit is implemented to provide surge and fast-transient protection and demonstrate the different immunity levels to (...)

Unterstützte Produkte und Hardware
Referenzdesign

TIDA-00570 — DLP®-Hochgeschwindigkeits-Subsystem für 3D-Druck und digitale Lithografie – Referenzdesign

The High Speed DLP® Sub-system Reference Design provides system-level DLP development board designs for industrial Digital Lithography and 3D Printing applications that require high resolution, superior speed and production reliability. The system design offers maximum throughput by integrating (...)

Unterstützte Produkte und Hardware
Referenzdesign

TIDM-HAHSCPTO — Hochverfügbarer Hochgeschwindigkeitszähler (HSC) und Impulswellenausgang (PTO) 0 Referenzdesign

Dieses Referenzdesign bietet Firmware und Testplattform für zwei verschiedene industrielle Eingangs-/Ausgangsfunktionen im Zusammenhang mit Bewegungssteuerung: Highspeed-Zähler (High-Speed Counter, HSC) und Impulsfolgeausgang (Pulse-Train Output, PTO). Das Design basiert auf einer (...)
Unterstützte Produkte und Hardware
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
UQFN (RSW) 10 Ultra Librarian
SOT-SC70 (DCK) 6 Ultra Librarian

Bestellen & Qualität

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videoreihe

Alle Videos anzeigen

Videos