ZHCSHG1C October 2017 – February 2018 UCC28056
PRODUCTION DATA.
| 参数 | 测试条件 | 最小值 | 典型值 | 最大值 | 单位 | |
|---|---|---|---|---|---|---|
| 电源电压 | ||||||
| VCCStart | 导通阈值 | VCC 上升 | 10.65 | 11 | V | |
| VCCStop | 断开阈值 | VCC 下降 | 8.5 | 8.85 | 9.2 | V |
| VCCHyst | UVLO 迟滞 (VCCStart - VCCStop) (1) | 1.5 | V | |||
| TUVLOBlk | 断开消隐时间 | 27 | 35 | 42 | µs | |
| 电源电流 | ||||||
| ICC_Startup | 启动前的电流消耗 | VCC = VCCStart-200mV,TA< 110℃ | 46 | µA | ||
| ICC_FAULT | 故障状况期间的电流消耗 | VCC = 12V | 130 | µA | ||
| ICC_BSTOFF | 间歇关闭期间的电流消耗 | VCC = 12V | 132 | µA | ||
| ICC_RUN | DRV 引脚空载时的工作电流 | VCC = 12V | 1.8 | 2.2 | mA | |
| 栅极驱动 | ||||||
| VDRLow | DRV 输出低电压 | IDR = 100mA | 0.9 | V | ||
| VDRHigh | DRV 输出电压高电平(限制) | VCC = 25V,IDR = -10mA | 10 | 13.7 | 15 | V |
| VDRHighMin | DRV 最低高电压电平 | VCC = VCCStop + 200mV,IDR = -8mA | 8 | V | ||
| RDRH | DRV,上拉电阻 | TA = -40°C 至 125°C,IDR = -8mA,VCC=12V | 9.7 | 16 | Ω | |
| RDRL | DRV,下拉电阻 | TA = -40°C 至 125°C,IDR = 100mA | 2.0 | 4.6 | 9 | Ω |
| tR | 上升时间 | CLOAD = 1nF,DRV = 1V 至 6V,VCC = 12V | 10 | 34 | 61 | ns |
| tF | 下降时间 | CLOAD = 1nF,DRV = 6V 至 1V,VCC = 12V | 4 | 15 | 40 | ns |
| Isource | DRV 引脚上的峰值源电流 (1) | -0.7 | A | |||
| Isink | DRV 引脚上的峰值灌电流 (1) | 1 | A | |||
| RDG0 | 选择 TZCDR0 时的 DRV 接地电阻值 (1) | 130 | 200 | kΩ | ||
| RDG1 | 选择 TZCDR1 时的 DRV 接地电阻值 (1) | 81.18 | 82 | 82.82 | kΩ | |
| RDG2 | 选择 TZCDR2 时的 DRV 接地电阻值 (1) | 61.38 | 62 | 62.62 | kΩ | |
| RDG3 | 选择 TZCDR3 时的 DRV 接地电阻值 (1) | 42.57 | 43 | 43.43 | kΩ | |
| RDG4 | 选择 TZCDR4 时的 DRV 接地电阻值 (1) | 26.73 | 27 | 27.27 | kΩ | |
| RDG5 | 选择 TZCDR5 时的 DRV 接地电阻值 (1) | 17.82 | 18 | 18.18 | kΩ | |
| RDG6 | 选择 TZCDR6 时的 DRV 接地电阻值 (1) | 12.87 | 13 | 13.13 | kΩ | |
| RDG7 | 选择 TZCDR7 时的 DRV 接地电阻值 (1) | 9 | 9.1 | 9.2 | kΩ | |
| TDGSmpl | 检测到 RDG 值所需的时间。 | TA< 85℃ | 3.95 | 4.4 | 4.95 | ms |
| VDGClmp | 检测 RDG 值时在 DRV 引脚上施加的最大电压。 | 1 | 1.05 | 1.1 | V | |
| 误差放大器 | ||||||
| VOSReg | 反馈电压基准 | 2.45 | 2.5 | 2.55 | V | |
| IOSBias | ISNS 引脚偏置电流 | VOS = VOSReg | -100 | 100 | nA | |
| gM | 误差放大器跨导增益 | |VOS-VOSReg| < DSuThs | 50 | µS | ||
| gMNL | 适用于较大误差的误差放大器跨导增益 | |VOS-VOSReg| > DSuThs | 300 | µS | ||
| DSuThs | 非线性增益阈值 | 67 | mV | |||
| RCODisch | 处于 STOPb 状态时的内部 COMP 接地电阻。 | 4.3 | 5 | 5.7 | kΩ | |
| VCOClmp | COMP 引脚内部高钳位电压 | 5.5 | 5.6 | 5.71 | V | |
| VCOSat | COMP 引脚内部低钳位电压 (1) | 0 | V | |||
| ICOMin | COMP 源电流 | -120 | µA | |||
| ICOMax | COMP 最大灌电流 | 120 | µA | |||
| 线电压前馈 | ||||||
| THLinMax | 线路峰值采样窗口 (1) | 打开开关时 | 11 | 12.3 | 13.6 | ms |
| VFF0Rise | 从 GFF0 切换到 GFF1 时的比较器上升阈值 (1) | 0.348 | V | |||
| VFF1Rise | 从 GFF1 切换到 GFF2 时的比较器上升阈值 (1) | 0.406 | V | |||
| VFF2Rise | 从 GFF2 切换到 GFF3 时的比较器上升阈值 (1) | 0.473 | V | |||
| VFF3Rise | 从 GFF3 切换到 GFF4 时的比较器上升阈值 (1) | 0.552 | V | |||
| VFF4Rise | 从 GFF4 切换到 GFF5 时的比较器上升阈值 (1) | 0.644 | V | |||
| VFF5Rise | 从 GFF5 切换到 GFF6 时的比较器上升阈值 (1) | 0.751 | V | |||
| VFF6Rise | 从 GFF6 切换到 GFF7 时的比较器上升阈值 (1) | 0.875 | V | |||
| VFF0Fall | 从 GFF1 切换到 GFF0 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.331 | V | ||
| VFF1Fall | 从 GFF2 切换到 GFF1 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.386 | V | ||
| VFF2Fall | 从 GFF3 切换到 GFF2 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.45 | V | ||
| VFF3Fall | 从 GFF4 切换到 GFF3 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.524 | V | ||
| VFF4Fall | 从 GFF5 切换到 GFF4 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.612 | V | ||
| VFF5Fall | 从 GFF6 切换到 GFF5 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.713 | V | ||
| VFF6Fall | 从 GFF7 切换到 GFF6 时的比较器下降阈值 (1) | THLinMax 窗口内的 VInSynth 峰值 | 0.832 | V | ||
| GFF0 | 线路前馈增益电平 0 (1) | 1 | V | |||
| GFF1 | 线路前馈增益电平 1 (1) | 0.735 | V | |||
| GFF2 | 线路前馈增益电平 2 (1) | 0.541 | V | |||
| GFF3 | 线路前馈增益电平 3 (1) | 0.398 | V | |||
| GFF4 | 线路前馈增益电平 4 (1) | 0.292 | V | |||
| GFF5 | 线路前馈增益电平 5 (1) | 0.215 | V | |||
| GFF6 | 线路前馈增益电平 6 (1) | 0.158 | V | |||
| GFF7 | 线路前馈增益电平 7 (1) | 0.116 | V | |||
| 最大导通时间 | ||||||
| TONMAX0 | 最大导通时间 (GFF = GFF0) | 12.1 | 12.8 | 13.2 | µs | |
| TONMAX1 | 最大导通时间 (GFF = GFF1) | 10.42 | 10.98 | 11.28 | µs | |
| TONMAX2 | 最大导通时间 (GFF = GFF2) | 8.85 | 9.41 | 9.64 | µs | |
| TONMAX3 | 最大导通时间 (GFF = GFF3) | 7.59 | 8.07 | 8.32 | µs | |
| TONMAX4 | 最大导通时间 (GFF = GFF4) | 6.52 | 6.92 | 7.18 | µs | |
| TONMAX5 | 最大导通时间 (GFF = GFF5) | 5.56 | 5.93 | 6.16 | µs | |
| TONMAX6 | 最大导通时间 (GFF = GFF6) | 4.73 | 5.09 | 5.28 | µs | |
| TONMAX7 | 最大导通时间 (GFF = GFF7) | 4.07 | 4.36 | 4.57 | µs | |
| 间歇模式运行 | ||||||
| VBSTFall | VCOMP 间歇阈值下降 | 0.5 | V | |||
| VBSTRise | VCOMP 间歇阈值上升 | 0.625 | V | |||
| 零电流检测和谷值同步 | ||||||
| VZcdVinHyst | ZcdVin 比较器回差 (1) | 12 | 19 | 26 | mV | |
| TDCHVinMin | ZcdVin 比较器从 DRV 下降沿开始的消隐时间 (1) | 250 | 358 | 467 | ns | |
| TZCDTo | 如果 Vin 比较器在此期间没有出现负跳变,则不等待谷值 | 2.035 | 2.4 | 3.0 | µs | |
| TZCDR0 | ZCD 至 DRV 最小延迟。 | 从 VZC< VInSynth 到 DRV = 6V,CDR = 1nF,Fres = 1.2MHz,RDG = RDG0 | 170 | 235 | ns | |
| ΔTZCDR1 | TZCDR1 = TZCDR0 + ΔTZCDR1 (1) | RDG = RDG1 | 34.6 | 45.5 | 58.5 | ns |
| ΔTZCDR2 | TZCDR2 = TZCDR0 + ΔTZCDR2 (1) | RDG = RDG2 | 76 | 90 | 107 | ns |
| ΔTZCDR3 | TZCDR3 = TZCDR0 + ΔTZCDR3 (1) | RDG = RDG3 | 114 | 130 | 147 | ns |
| ΔTZCDR4 | TZCDR4 = TZCDR0 + ΔTZCDR4 (1) | RDG = RDG4 | 157 | 175 | 193 | ns |
| ΔTZCDR5 | TZCDR5 = TZCDR0 + ΔTZCDR5 (1) | RDG = RDG5 | 229 | 255 | 281 | ns |
| ΔTZCDR6 | TZCDR6 = TZCDR0 + ΔTZCDR6 (1) | RDG = RDG6 | 301 | 335 | 369 | ns |
| ΔTZCDR7 | TZCDR7 = TZCDR0 + ΔTZCDR7 (1) | RDG = RDG7 | 373 | 415 | 457 | ns |
| VDDAmpl | 触发拐点检测器时所需的 ZCD/CS 引脚上的 500kHz 正弦波信号振幅 | 25 | mV | |||
| TDCHDDMin | 拐点检测器消隐周期 (1) | 从 DRV 脉冲下降沿开始测得 | 1.5 | µs | ||
| 故障保护 | ||||||
| TLongFlt | 长故障持续时间 (1) | 1 | s | |||
| 线路欠压启动保护 | ||||||
| VZCBoRise | 处于 Stopb 状态时的欠压保护阈值 | ZCD/CS 引脚上的峰值周期平均电压。 | 0.282 | 0.3 | 0.318 | V |
| IZCBias | ZCD/CS 引脚偏置电流 (1) | VZC = VZCBoFall | -100 | 100 | nA | |
| 过流保护 | ||||||
| VZCOcp1 | ZCD/CS 一级过流保护阈值 | 450 | 500 | 550 | mV | |
| VZCOcp2 | ZCD/CS 二级过流保护阈值 | 670 | 750 | 825 | mV | |
| TOcp1Blk | 从 DRV 上升沿到启用 Ocp1 比较器输出的 ZCD/CS 消隐时间 (1) | 450 | ns | |||
| TOcp2Blk | 从 DRV 上升沿到启用 Ocp2 比较器输出的 ZCD/CS 消隐时间 (1) | 250 | ns | |||
| TOcpDrvDel | ZCD/CS 穿越 VOcpxTh 到 DRV 下降沿。 | 56 | 120 | ns | ||
| TDCHMax0 | 未检测到 ZCD 信号时 TDCHb 状态的最大持续时间。从不出现 OCPx 事件开始计算 (1) | 250 | µS | |||
| TDCHMax1 | 未检测到 ZCD 信号时 TDCHb 状态的最大持续时间。从出现一次 OCPx 事件开始计算 (1) | 500 | µS | |||
| TDCHMax2 | 未检测到 ZCD 信号时 TDCHb 状态的最大持续时间。从连续出现两次 OCPx 事件开始计算 (1) | 1000 | µS | |||
| 输出过压保护 | ||||||
| VOSOovp1Rise | VOSNS 过压阈值(上升) | VCC=12V | 2.69 | 2.75 | 2.81 | V |
| VOSOovp1Fall | VOSNS 过压阈值(下降) | VCC=12V | 2.60 | 2.675 | 2.73 | V |
| VOSOovp1Hyst | VOSOovp1Rise - VOSOovp1Fall(1) | 0.072 | V | |||
| TOvp2Blk | 在DRV下降沿之后,Ovp2比较器输出消隐时间 (1) | 520 | 620 | 720 | ns | |
| TOvp2bEn | 在 Ovp3 比较器输出下降沿后的一段时间内,检测到 Ovp2b 故障和 ZCD (1) | 620 | 720 | 820 | ns | |
| VOvp2Th | 二级输出过压故障阈值 | 1.102 | 1.125 | 1.148 | V | |
| 热保护 | ||||||
| TTSDRise | 热关断上升阈值 (1) | 打开开关时 | 135 | 145 | 155 | °C |
| TTSDFall | 热关断下降阈值 (1) | 关闭开关时 | 95 | 105 | 115 | °C |
| TTSDHyst | TTSDRise - TTSDFall(1) | 38 | 40 | 42 | °C | |