SLOK017 June   2024 TLV1H103-SEP

PRODUCTION DATA  

  1.   1
  2. 1 TLV1H103-SEP Single-Event Effects (SEE) Radiation Report
  3.   Trademarks
  4. 2 Overview
  5. 3 SEE Mechanisms
  6. 4 Test Device and Test Board Information
  7. 5 Irradiation Facility and Setup
  8. 6 Results
    1. 6.1 Single Event Latchup (SEL) Results
    2. 6.2 Single Event Transient (SET) Results
  9. 7 Summary
  10. 8 SET Results Appendix
  11. 9 Confidence Interval Calculations
  12. 10References

TLV1H103-SEP Single-Event Effects (SEE) Radiation Report

The purpose of this study was to characterize the effects of heavy-ion irradiation on the single-event latch-up (SEL) performance of the TLV1H103-SEP 5.5V, high speed comparator. Heavy-ions with an LETEFF of 48.47MeV-cm2/mg were used to irradiate the device with a fluence of 1 × 107 ions/cm2. The results demonstrate that the TLV1H103-SEP is SEL-immune up to LETEFF = 43MeV-cm2/mg at 125°C.

Characterization of single-event transients (SET) was also performed, up to a surface LETEFF = 50MeV-cm2 / mg at 125°C.