SBOK082 December   2024 TRF0208-SEP

 

  1.   1
  2.   2
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  6. 3Total Ionizing Dose Characterization Test Results
    1. 3.1 Total Ionizing Dose RHA Characterization Summary Results
  7. 4Applicable and Reference Documents
    1. 4.1 Reference Documents
  8. 5HDR Total Ionizing Dose Report

Abstract

This report discusses the radiation characterization results of the TRF0208-SEP, an 11GHz 3dB BW, single ended to differential ADC driver amplifier. The study was done to determine Total Ionizing Dose (TID) effects under high dose rate (HDR) up to 50krad(Si). The results show that all samples passed well within the specified limits up to 30krad(Si).