6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)(2)
|
MIN |
MAX |
UNIT |
| VPWR
|
5-V DC supply voltage for internal circuitry |
–0.3 |
7.7
|
V |
| VREF
|
Pin to set OVP threshold |
–0.3 |
6 |
V |
| VD+, VD– |
Voltage range from connector-side USB data lines |
–0.3 |
18 |
V |
| D+, D– |
Voltage range for internal USB data lines |
–0.3 |
VREF + 0.3 |
V |
| VMODE
|
Voltage on MODE pin |
–0.3 |
7.7 |
V |
| VFLT
|
Voltage on FLT pin |
–0.3 |
7.7 |
V |
| VEN
|
Voltage on enable pin |
–0.3 |
7.7 |
V |
| TA
|
Operating free air temperature(3)
|
–40 |
125 |
°C |
| TSTG
|
Storage temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(3) Thermal limits and power dissipation limits must be observed.