ZHCSIX4H August   2007  – December 2018 TMP102

PRODUCTION DATA.  

  1. 特性
  2. 应用
    1.     简化电路原理图
  3. 说明
    1.     方框图
  4. 修订历史记录
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 Handling Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Digital Temperature Output
        1. Table 2. 12-Bit Temperature Data Format
      2. 7.3.2  Serial Interface
      3. 7.3.3  Bus Overview
      4. 7.3.4  Serial Bus Address
      5. 7.3.5  Writing and Reading Operation
      6. 7.3.6  Slave Mode Operations
        1. 7.3.6.1 Slave Receiver Mode
        2. 7.3.6.2 Slave Transmitter Mode
      7. 7.3.7  SMBus Alert Function
      8. 7.3.8  General Call
      9. 7.3.9  High-Speed (HS) Mode
      10. 7.3.10 Timeout Function
      11. 7.3.11 Timing Diagrams
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuos-Conversion Mode
      2. 7.4.2 Extended Mode (EM)
      3. 7.4.3 Shutdown Mode (SD)
      4. 7.4.4 One-Shot/Conversion Ready (OS)
      5. 7.4.5 Thermostat Mode (TM)
        1. 7.4.5.1 Comparator Mode (TM = 0)
        2. 7.4.5.2 Interrupt Mode (TM = 1)
    5. 7.5 Programming
      1. 7.5.1 Pointer Register
        1. Table 7. Pointer Addresses
      2. 7.5.2 Temperature Register
        1. Table 8. Byte 1 of Temperature Register
        2. Table 9. Byte 2 of Temperature Register
      3. 7.5.3 Configuration Register
        1. Table 10. Byte 1 of Configuration and Power-Up or Reset Format
        2. Table 11. Byte 2 of Configuration and Power-Up or Reset Format
        3. 7.5.3.1   Shutdown Mode (SD)
        4. 7.5.3.2   Thermostat Mode (TM)
        5. 7.5.3.3   Polarity (POL)
        6. 7.5.3.4   Fault Queue (F1/F0)
        7. 7.5.3.5   Converter Resolution (R1/R0)
        8. 7.5.3.6   One-Shot (OS)
        9. 7.5.3.7   EM Bit
        10. 7.5.3.8   Alert (AL Bit)
        11. 7.5.3.9   Conversion Rate (CR)
      4. 7.5.4 High- and Low-Limit Registers
        1. Table 13. Byte 1 Temperature Register HIGH
        2. Table 14. Byte 2 Temperature Register HIGH
        3. Table 15. Byte 1 Temperature Register LOW
        4. Table 16. Byte 2 Temperature Register LOW
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11器件和文档支持
    1. 11.1 文档支持
      1. 11.1.1 相关文档
    2. 11.2 接收文档更新通知
    3. 11.3 社区资源
    4. 11.4 商标
    5. 11.5 静电放电警告
    6. 11.6 术语表
  12. 12机械、封装和可订购信息

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Continuos-Conversion Mode

The default mode of the TMP102 device is continuos conversion mode. During continuos-conversion mode, the ADC performs continuos temperature conversions and stores each results to the temperature register, overwriting the result from the previous conversion. The conversion rate bits, CR1 and CR0, configure the TMP102 device for conversion rates of 0.25 Hz, 1 Hz, 4 Hz, or 8 Hz. The default rate is 4 Hz. The TMP102 device has a typical conversion time of 26 ms. To achieve different conversion rates, the TMP102 device makes a conversion and then powers down to wait for the appropriate delay set by CR1 and CR0. Table 5 lists the settings for CR1 and CR0.

Table 5. Conversion Rate Settings

CR1 CR0 CONVERSION RATE
0 0 0.25 Hz
0 1 1 Hz
1 0 4 Hz (default)
1 1 8 Hz

After power-up or general-call reset, the TMP102 immediately starts a conversion, as shown in Figure 11. The first result is available after 26 ms (typical). The active quiescent current during conversion is 40 μA (typical at +27°C). The quiescent current during delay is 2.2 μA (typical at +27°C).

TMP102 ai_conv_bos397.gif
Delay is set by CR1 and CR0.
Figure 11. Conversion Start