ZHCSSF8A September 2000 – August 2023 INA141
PRODUCTION DATA
The inputs of the INA141 are individually protected for voltages up to ±40 V. For example, a condition of –40 V on one input and +40 V on the other input does not cause damage. Internal circuitry on each input provides low series impedance under normal signal conditions. To provide equivalent protection, series input resistors contributes excessive noise. If the input is overloaded, the protection circuitry limits the input current to a safe value of approximately 1.50 mA to 5 mA. The inputs are protected even if the power supplies are disconnected or turned off.
Figure 7-4 ECG Amplifier With Right-Leg Drive
Figure 7-5 Bridge Amplifier
Figure 7-6 AC-Coupled Instrumentation Amplifier
Figure 7-7 Thermocouple Amplifier With RTD Cold-Junction
Compensation
Figure 7-8 Differential Voltage-to-Current
Converter