SLVK144 august   2023 TL1431-SP

PRODUCTION DATA  

  1.   1
  2.   2
  3.   Trademarks
  4. 1Overview
  5. 2Test Procedures
  6. 3Facility
  7. 4Results
  8. 5Data Sheet Electrical Parameters and Associated Tests
  9.   A Appendix: Test Results

Test Procedures

The TL1431-SP was electrically pre- and post-tested using the production automated test equipment program.

General test procedures adhered to MIL-STD-883, Method 1017 for Neutron Irradiation of TL1431-SP. Neutron irradiation conditions are listed in Table 2-1.

Table 2-1 Neutron Irradiation Conditions
Group Sample Qty Neutron Fluence (n/cm2) Bias
A31.0 × 1012Unbiased
B35.0 × 1012Unbiased
C31.0 × 1013Unbiased
GUID-20230630-SS0I-WWD0-6ZJZ-LLTT6RZ2LJH0-low.jpg Figure 2-1 TL1431-SP Device (Front)
GUID-20230630-SS0I-NL1W-RHM4-DTF3H479TCWP-low.jpg Figure 2-2 TL1431-SP Device (Back)