ADC_ERR_04

The trim of ADC offset error is not correctly applied

Revisions Affected

Rev A

Details

The value of ADC offset error trim is not correctly applied. As a result, the offset can be in the range of +/-10mV.

This issue is going to be resolved in next version.

Workaround

Implement the user's own calibration and compensating the offset during the ADC measurement.