Core saturation
00:16:19
|
2021 年 3 月 26 日
In this lecture, we will learn:
- Core materials can only support so much B field before saturating.
- In saturation, the core permeability become ineffective.
- Saturation is almost always avoided in power conversion applications.
- Designs can use more turns and larger gaps to avoid saturations with the same inductance.