How High-Voltage Isolation Technology Works –Reliability Testing
00:09:48
|
2018 年 3 月 1 日
Learn more about reliability testing for isolation, focusing on the reliability of the working voltage of reinforced isolation. After a review of TI's reinforced isolation technology structure, dive into reliability tests like TDDB, the standard method to determine the lifetime of a dielectric as a function of voltage and Method B1 and Method A high-voltage testing. The video also explains different insulator materials and their tested dielectric strengths.
资源
此视频是该系列的一部分
-
高压研讨会
video-playlist (69 videos)