產品詳細資料

Vrwm (V) 27 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 950 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 29.6 Number of channels 1 IO capacitance (typ) (pF) 40 Clamping voltage (V) 34
Vrwm (V) 27 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 950 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 29.6 Number of channels 1 IO capacitance (typ) (pF) 40 Clamping voltage (V) 34
VSON (DRB) 8 9 mm² (3 mm × 3 mm)
  • Protection Against 1-kV, 42-Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines
  • Bidirectional Polarity Enables Protection Against Bipolar Signaling or Miswiring Conditions
  • Clamping Voltage of 34 V at 27-A, 8/20-µs Surge Current
  • Standoff Voltage: ±27 V
  • Small 3 mm × 3 mm2 SON Footprint
  • Survives Over 5,000 Repetitive Strikes of 27-A 8/20-µs Surge Current at 125°C
  • Robust Surge Protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3.5 A
  • Low Leakage Current
    • 0.8-nA Typical at 27°C
    • 400-nA Maximum at 85°C
  • Low Capacitance: 57 pF
  • Integrated Level 4 IEC 61000-4-2 ESD Protection
  • Protection Against 1-kV, 42-Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines
  • Bidirectional Polarity Enables Protection Against Bipolar Signaling or Miswiring Conditions
  • Clamping Voltage of 34 V at 27-A, 8/20-µs Surge Current
  • Standoff Voltage: ±27 V
  • Small 3 mm × 3 mm2 SON Footprint
  • Survives Over 5,000 Repetitive Strikes of 27-A 8/20-µs Surge Current at 125°C
  • Robust Surge Protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3.5 A
  • Low Leakage Current
    • 0.8-nA Typical at 27°C
    • 400-nA Maximum at 85°C
  • Low Capacitance: 57 pF
  • Integrated Level 4 IEC 61000-4-2 ESD Protection

The TVS2701 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS2701 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS2701 has a ±27-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS2701 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS2701 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS2701 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

The TVS2701 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS2701 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS2701 has a ±27-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS2701 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS2701 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS2701 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

下載 觀看有字幕稿的影片 影片

查看 TI.com 庫存中的類似產品

規格相似的產品依可用的 TI.com 庫存排序。

立即檢視

技術文件

找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 7
重要文件 類型 標題 格式選項 下載最新的英文版本 日期
* 資料表 TVS2701 27-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. A) PDF | HTML 2018/12/4
應用說明 ESD Packaging and Layout Guide (Rev. B) PDF | HTML 2022/8/18
Application brief Protecting I/O modules from surge events 2019/2/4
Application brief TVS Surge Rating: Power vs. Current 2018/11/12
白皮書 Demystifying surge protection 2018/11/6
使用指南 Flat Clamp TVS Evaluation Module—Adaptor Boards 2018/9/10
應用說明 How to select a Surge Diode 2018/8/29

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

FLAT-CLAMP-TVS-EVM — TVSxx0x 精密突波防護二極體評估模組

平箝位 TVS-EVM(精密突波防護二極體轉接器板評估模組)展示了 TVSxx0x 系列裝置的特性、運作及使用。TVSxx0x 系列裝置為精密固定夾,可在雙向與單向訊號突波等暫態過電壓事件期間維持超低與平箝位電壓。這些轉接器電路板可將 TVSxx00 裝置的小型 DRV 封裝尺寸和 TVSxx01 裝置的小型 DRB 封裝尺寸轉換成更大的尺寸,專為符合業界標準 SMA 和 SMB 封裝類型而設計,並允許使用者在自己的系統中測試性能。
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
模擬型號

TVS2701 PSpice Transient Model

SLVMCT2.ZIP (52 KB) - PSpice 模型
支援產品和硬體
參考設計

TIDA-010008 — 適合電網應用瞬態保護的平箝制 TVS 架構參考設計

此參考設計具備多種方式,可保護 AC 或 DC 類比輸入、DC 類比輸出、AC 或 DC 二進位輸入、配備高側或低側驅動器的數位輸出、LCD 偏壓供應器、USB 介面 (電源和資料) 和內建電源供應器,並在多個電網應用中使用 24、12 或 5V 輸入,以防止過電壓、過載和暫態 (1.2/50μs、42-Ω),並使用平箝制突波保護裝置、ESD 裝置、eFuse 或負載開關。此設計可監控溫度、濕度、磁場和電源供應器以進行診斷。
支援產品和硬體
封裝 針腳 CAD 符號、佔位空間與 3D 模型
VSON (DRB) 8 Ultra Librarian

訂購與品質

建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片