TVS1401
- Functional safety-capable
- Protection against 1 kV, 42 Ω IEC 61000-4-5 surge test for industrial signal lines
- Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
- Clamping voltage of 20.5 V at 30 A of 8/20 µs surge current
- Standoff voltage: ±14 V
- Small 3-mm × 3-mm SON footprint
- Survives over 5,000 repetitive strikes of 30 A 8/20 µs surge current at 125°C
- Robust surge protection
- IEC61000-4-5 (8/20 µs): 30 A
- IEC61643-321 (10/1000 µs): 6 A
- Low leakage current
- 1.1 nA typical at 27°C
- 260 nA maximum at 85°C
- Low capacitance: 68 pF
- Integrated Level 4 IEC 61000-4-2 ESD protection
The TVS1401 device shunts up to 30 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1 kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS1401 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS1401 has a ±14 V operating range to enable operation in systems that require protection against reverse wiring conditions.
In addition, the TVS1401 is available in a small SON footprint which is designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS1401 against 5,000 repetitive surge strikes at 125°C with no shift in device performance.
The TVS1401 is part of TIs Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.
技術文件
| 重要文件 | 類型 | 標題 | 格式選項 | 下載最新的英文版本 | 日期 | |
|---|---|---|---|---|---|---|
| * | 資料表 | TVS1401 14-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. B) | PDF | HTML | 2021/11/1 | ||
| 應用說明 | ESD Packaging and Layout Guide (Rev. B) | PDF | HTML | 2022/8/18 | |||
| Circuit design | Circuit for Protecting ADS124S08 ADC From EOS for RTD Measurement | PDF | HTML | 2022/5/24 | |||
| 功能安全資訊 | TVS1401 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA | PDF | HTML | 2021/9/27 | |||
| Application brief | Protecting I/O modules from surge events | 2019/2/4 | ||||
| Application brief | TVS Surge Rating: Power vs. Current | 2018/11/12 | ||||
| 白皮書 | Demystifying surge protection | 2018/11/6 | ||||
| 應用說明 | How to select a Surge Diode | 2018/8/29 | ||||
| Application brief | Flat-Clamp TVS Layout in SMA/SMB Footprints | 2018/4/3 | ||||
| 應用說明 | TVS Surge Protection in High-Temperature Environments | 2018/3/23 |
設計與開發
如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。
FLAT-CLAMP-TVS-EVM — TVSxx0x 精密突波防護二極體評估模組
TIDA-00834 — 使用具有 ±10V 量測範圍之 16 位元 SAR ADC 的高準確度類比前端參考設計
TIDA-010008 — 適合電網應用瞬態保護的平箝制 TVS 架構參考設計
TIDA-010026 — 適用於 EnDat2.2 絕對編碼器的耐用介面參考設計
TIDA-01606 — 11-kW、雙向三相三級 (T 型) 逆變器和 PFC 參考設計
| 封裝 | 針腳 | CAD 符號、佔位空間與 3D 模型 |
|---|---|---|
| VSON (DRB) | 8 | Ultra Librarian |
訂購與品質
建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。