- Protection Against 1-kV, 42-Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines
- Bidirectional Polarity Enables Protection Against Bipolar Signaling or Miswiring Conditions
- Clamping Voltage of 11 V at 30-A, 8/20-µs Surge Current
- Standoff Voltage: ±7 V
- Small 3-mm × 3-mm SON Footprint
- Survives Over 5,000 Repetitive Strikes of 30-A, 8/20-µs Surge Current at 125°C
- Robust Surge Protection
- IEC61000-4-5 (8/20 µs): 30 A
- IEC61643-321 (10/1000 µs): 15 A
- Low Leakage Current
- 0.25-nA Typical at 27°C
- 200-nA Maximum at 85°C
- Low Capacitance: 77 pF
- Integrated Level 4 IEC 61000-4-2 ESD Protection
The TVS0701 device shunts up to 30 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS0701 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS0701 has a ±7-V operating range to enable operation in systems that require protection against reverse wiring conditions.
In addition, the TVS0701 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS0701 against 5000 repetitive surge strikes at 125°C with no shift in device performance.
The TVS0701 is part of TIs Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.
技術文件
| 重要文件 | 類型 | 標題 | 格式選項 | 下載最新的英文版本 | 日期 | |
|---|---|---|---|---|---|---|
| * | 資料表 | TVS0701 7-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. A) | PDF | HTML | 2018/12/7 | ||
| 應用說明 | ESD Packaging and Layout Guide (Rev. B) | PDF | HTML | 2022/8/18 | |||
| Application brief | Protecting I/O modules from surge events | 2019/2/4 | ||||
| Application brief | TVS Surge Rating: Power vs. Current | 2018/11/12 | ||||
| 白皮書 | Demystifying surge protection | 2018/11/6 | ||||
| 使用指南 | Flat Clamp TVS Evaluation Module—Adaptor Boards | 2018/9/10 | ||||
| 應用說明 | How to select a Surge Diode | 2018/8/29 | ||||
| 類比設計期刊 | Design Considerations for System-Level ESD Circuit Protection | 2012/9/25 |
設計與開發
如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。
FLAT-CLAMP-TVS-EVM — TVSxx0x 精密突波防護二極體評估模組
TIDA-00420 — ADC 架構、數位隔離、廣泛輸入、16 通道、AC/DC 二進位輸入參考設計
此參考設計展現具強化型隔離的成本最佳化、可擴充 ADC 架構 AC/DC 二進位輸入模組 (BIM) 架構。10 位元或 12 位元 SAR ADC 的 16 通道,用於感測多個二進位輸入。運算放大器除了維持低每頻道成本外,也可為各輸入提供最佳訊號調節。數位隔離器 (基本型或強化型) 可用於隔離主機 MCU 或處理器。提供可測量溫度,濕度和磁場以進行診斷的設備。具可配置輸出的強化型隔離 DC/DC 電源供應器,可提供二進位模組所需的電源。
TIDA-010008 — 適合電網應用瞬態保護的平箝制 TVS 架構參考設計
| 封裝 | 針腳 | CAD 符號、佔位空間與 3D 模型 |
|---|---|---|
| VSON (DRB) | 8 | Ultra Librarian |
訂購與品質
建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。