產品詳細資料

Type Time-to-digital converter Number of input channels 1 Supply voltage (min) (V) 2 Supply voltage (max) (V) 3.6 Operating temperature range (°C) -40 to 85 Interface type SPI Rating Catalog
Type Time-to-digital converter Number of input channels 1 Supply voltage (min) (V) 2 Supply voltage (max) (V) 3.6 Operating temperature range (°C) -40 to 85 Interface type SPI Rating Catalog
TSSOP (PW) 14 32 mm² 5 x 6.4
  • Resolution: 55 ps
  • Standard Deviation: 35 ps
  • Measurement Range:
    • Mode 1: 12 ns to 500 ns
    • Mode 2: 250 ns to 8 ms
  • Low Power Consumption: 0.5 µA (2 SPS)
  • Supports up to 5 STOP Signals
  • Autonomous Multi-Cycle Averaging Mode for Low
    Power Consumption
  • Supply Voltage: 2 V to 3.6 V
  • Operating Temperature –40°C to 85°C
  • SPI Host Interface for Configuration and Register
    Access
  • Resolution: 55 ps
  • Standard Deviation: 35 ps
  • Measurement Range:
    • Mode 1: 12 ns to 500 ns
    • Mode 2: 250 ns to 8 ms
  • Low Power Consumption: 0.5 µA (2 SPS)
  • Supports up to 5 STOP Signals
  • Autonomous Multi-Cycle Averaging Mode for Low
    Power Consumption
  • Supply Voltage: 2 V to 3.6 V
  • Operating Temperature –40°C to 85°C
  • SPI Host Interface for Configuration and Register
    Access

The TDC7200 is a Time-to-Digital Converter (TDC) for ultrasonic sensing measurements such as water flow meter, gas flow meter, and heat flow meter. When paired with the TDC1000 (ultrasonic analog-front-end), the TDC7200 can be a part of a complete TI ultrasonic sensing solution that includes the MSP430, power, wireless, and source code.

The Time to Digital Converter (TDC) performs the function of a stopwatch and measures the elapsed time (time-of-flight or TOF) between a START pulse and up to five STOP pulses. The ability to measure from START to multiple STOPs gives users the flexibility to select which STOP pulse yields the best echo performance.

The device has an internal self-calibrated time base which compensates for drift over time and temperature. Self-calibration enables time-to-digital conversion accuracy in the order of picoseconds. This accuracy makes the TDC7200 ideal for flow meter applications, where zero and low flow measurements require high accuracy.

When placed in the Autonomous Multi-Cycle Averaging Mode, the TDC7200 can be optimized for low system power consumption, making it ideal for battery powered flow meters. In this mode, the host can go to sleep to save power, and it can wake up when interrupted by the TDC upon completion of the measurement sequence.

The TDC7200 is a Time-to-Digital Converter (TDC) for ultrasonic sensing measurements such as water flow meter, gas flow meter, and heat flow meter. When paired with the TDC1000 (ultrasonic analog-front-end), the TDC7200 can be a part of a complete TI ultrasonic sensing solution that includes the MSP430, power, wireless, and source code.

The Time to Digital Converter (TDC) performs the function of a stopwatch and measures the elapsed time (time-of-flight or TOF) between a START pulse and up to five STOP pulses. The ability to measure from START to multiple STOPs gives users the flexibility to select which STOP pulse yields the best echo performance.

The device has an internal self-calibrated time base which compensates for drift over time and temperature. Self-calibration enables time-to-digital conversion accuracy in the order of picoseconds. This accuracy makes the TDC7200 ideal for flow meter applications, where zero and low flow measurements require high accuracy.

When placed in the Autonomous Multi-Cycle Averaging Mode, the TDC7200 can be optimized for low system power consumption, making it ideal for battery powered flow meters. In this mode, the host can go to sleep to save power, and it can wake up when interrupted by the TDC upon completion of the measurement sequence.

下載 觀看有字幕稿的影片 影片

技術文件

star =TI 所選的此產品重要文件
找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 5
重要文件 類型 標題 格式選項 日期
* Data sheet TDC7200 Time-to-Digital Converter for Time-of-Flight Applications in LIDAR, Magnetostrictive and Flow Meters datasheet (Rev. D) PDF | HTML 2016年 3月 7日
Application note Interleaved Short Time Measurements Using TDC7200 2015年 10月 30日
Technical article Time-of-flight measurements using high-performance time-to-digital converters PDF | HTML 2015年 7月 31日
Technical article Why are flow meter manufacturers switching from mechanical to ultrasonic? PDF | HTML 2015年 6月 11日
Application note Measuring an RTD Sensor with the TDC1000 and TDC7200 for Ultrasonic Sensing 2015年 4月 9日

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

TDC7200EVM — TDC7200 評估模組

TDC7200EVM 是一款評估模組,可讓使用者評估 TDC7200 時間數位轉換器的操作和性能。計算飛行時間便是一個範例,不論是用於光達或超音波應用。TDC7200EVM 具有兩個用於啟動和停止脈衝的 SMA 連接器,該連接器連接至 MSP430 LaunchPad 評估套件以擷取資料。  EVM 配備簡單易用的圖形使用者介面 (GUI),可修改暫存器和顯示資料。

使用指南: PDF
TI.com 無法提供
模擬型號

TDC7200 IBIS Model

SNAM176.ZIP (37 KB) - IBIS Model
參考設計

TIDM-ULTRASONIC-FLOW-TDC — 使用時間轉數位轉換器進行超音波水錶設計

TIDM-ULTRASONIC-FLOW-TDC 是超音波流量計(水、瓦斯或熱能電表)的參考設計,搭載使用時間至數位轉換器和超低功率 MCU 建置的 LCD。解決方案具備最佳化的洩漏偵測、低功率以及尺寸小巧等特色,這些都是水表、熱能電表及瓦斯表應用的重要需求。此設計還包括適用於系統電源的高效率 DC-DC 轉換器。
Design guide: PDF
電路圖: PDF
參考設計

TIDA-00663 — 光達脈衝飛時測距參考設計

光線偵測與測距(光達)系統利用光在目標物間來回飛行所花費的時間,測量與此目標的距離。  TIDA-00663 參考設計展示如何根據時間轉數位轉換器 (TDC) 和相關前端,設計 LIDAR 的時間測量後端。  LIDAR 脈衝飛時測距參考設計適用於無法透過物理接觸來測量目標距離的各類應用。  典型的範例包括測量物流中心傳送帶上的物體,確保移動機器手臂周圍的安全距離等。
Design guide: PDF
電路圖: PDF
封裝 針腳 CAD 符號、佔位空間與 3D 模型
TSSOP (PW) 14 Ultra Librarian

訂購與品質

內含資訊:
  • RoHS
  • REACH
  • 產品標記
  • 鉛塗層/球物料
  • MSL 等級/回焊峰值
  • MTBF/FIT 估算值
  • 材料內容
  • 認證摘要
  • 進行中的可靠性監測
內含資訊:
  • 晶圓廠位置
  • 組裝地點

建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片