產品詳細資料

Rating Catalog Applications Enterprise Operating temperature range (°C) -40 to 85
Rating Catalog Applications Enterprise Operating temperature range (°C) -40 to 85
USON (DNP) 6 4 mm² 2 x 2
  • Wide Optical Spectrum: 300 nm to 1000 nm
  • Automatic Full-Scale Setting Feature Simplifies Software and Configuration
  • Measurement Levels:
    • 1.2 nW/cm2 to 10 mW/cm2
  • 23-Bit Effective Dynamic Range With
    Automatic Gain Ranging
  • 12 Binary-Weighted, Full-Scale Range Settings:
    < 0.2% (typ) Matching Between Ranges
  • Low Operating Current: 1.8 µA (typ)
  • Operating Temperature: –40°C to +85°C
  • Wide Power-Supply: 1.6 V to 3.6 V
  • 5.5-V Tolerant I/O
  • Flexible Interrupt System
  • Small Form Factor: 2.0 mm × 2.0 mm × 0.65 mm
  • Wide Optical Spectrum: 300 nm to 1000 nm
  • Automatic Full-Scale Setting Feature Simplifies Software and Configuration
  • Measurement Levels:
    • 1.2 nW/cm2 to 10 mW/cm2
  • 23-Bit Effective Dynamic Range With
    Automatic Gain Ranging
  • 12 Binary-Weighted, Full-Scale Range Settings:
    < 0.2% (typ) Matching Between Ranges
  • Low Operating Current: 1.8 µA (typ)
  • Operating Temperature: –40°C to +85°C
  • Wide Power-Supply: 1.6 V to 3.6 V
  • 5.5-V Tolerant I/O
  • Flexible Interrupt System
  • Small Form Factor: 2.0 mm × 2.0 mm × 0.65 mm

The OPT3002 light-to-digital sensor provides the functionality of an optical power meter within a single device. This optical sensor greatly improves system performance over photodiodes and photoresistors. The OPT3002 has a wide spectral bandwidth, ranging from 300 nm to 1000 nm. Measurements can be made from 1.2 nW/cm2 up to 10 mW/cm2, without the need to manually select the full-scale ranges by using the built-in, full-scale setting feature. This capability allows light measurement over a 23-bit effective dynamic range. The results are compensated for dark-current effects, as well as other temperature variations.

Use the OPT3002 in optical spectral systems that require detection of a variety of wavelengths, such as optically-based diagnostic systems. The interrupt pin system can summarize the result of the measurement with one digital pin. Power consumption is very low, allowing the OPT3002 to be used as a low-power, battery-operated, wake-up sensor when an enclosed system is opened.

The OPT3002 is fully integrated and provides optical power reading directly from the I2C- and SMBus-compatible, two-wire, serial interface. Measurements are either continuous or single-shot. The OPT3002 fully-operational power consumption is as low as 0.8 µW at 0.8 SPS on a 1.8-V supply.

 

The OPT3002 light-to-digital sensor provides the functionality of an optical power meter within a single device. This optical sensor greatly improves system performance over photodiodes and photoresistors. The OPT3002 has a wide spectral bandwidth, ranging from 300 nm to 1000 nm. Measurements can be made from 1.2 nW/cm2 up to 10 mW/cm2, without the need to manually select the full-scale ranges by using the built-in, full-scale setting feature. This capability allows light measurement over a 23-bit effective dynamic range. The results are compensated for dark-current effects, as well as other temperature variations.

Use the OPT3002 in optical spectral systems that require detection of a variety of wavelengths, such as optically-based diagnostic systems. The interrupt pin system can summarize the result of the measurement with one digital pin. Power consumption is very low, allowing the OPT3002 to be used as a low-power, battery-operated, wake-up sensor when an enclosed system is opened.

The OPT3002 is fully integrated and provides optical power reading directly from the I2C- and SMBus-compatible, two-wire, serial interface. Measurements are either continuous or single-shot. The OPT3002 fully-operational power consumption is as low as 0.8 µW at 0.8 SPS on a 1.8-V supply.

 

下載 觀看有字幕稿的影片 影片

技術文件

star =TI 所選的此產品重要文件
找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 3
類型 標題 日期
* Data sheet OPT3002 Light-to-Digital Sensor datasheet (Rev. A) PDF | HTML 2016年 6月 10日
Application brief How to Select a Light Sensor for Your Application (Rev. C) PDF | HTML 2024年 1月 19日
Technical article Understanding tamper detection sensors PDF | HTML 2019年 11月 18日

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

OPT3001EVM — 具有高精密度人眼反應的 OPT3001 數位環境光感測器 (ALS) 評估模組

The OPT3001 is an ambient light sensor (ALS) with a digital output integrated circuit.  It uses a two-wire interface that works with the I2C protocol making it ideal for many applications.  The OPT3001EVM is a platform for evaluating the performance of the OPT3001 under various (...)

使用指南: PDF
TI.com 無法提供
開發板

OPT3002EVM — OPT3002 光轉數位感測器評估模組

OPT3002 是具有數位輸出積體電路的環境光感測器 (ALS)。  它使用與 I2C 通訊協定相容的雙線介面,非常適合許多應用。  OPT3002EVM 是在各種條件下評估 OPT3002 性能的平台。  OPT3002EVM 由兩個 PCB 組成。第一個是 SM-USB-DIG 板,用來與電腦通訊、提供電源,以及傳送和接收適當的數位訊號。  第二個 為 OPT3002 測試板,其中包含 OPT3002 及其支援電路。
使用指南: PDF
TI.com 無法提供
開發套件

LIGHTSOURCE01EVM — 適用於校準 TI 周圍光源感測器評估模組的穩定光源

LIGHTSOURCE01EVM 是穩定且一致的光源,可用於校準周圍光源感測器 (ALS) 和色彩感測器。此光源專為在生產環境中使用而設計,可校準和測試內含 TI 光源感測器的最終產品。此穩定光源可用於模擬日落 (4200K CCT) 和中午 (6400K CCT) 照明模式。光源均勻且恆定,光輸出隨時間的變化小於 ±1%,且 1 英寸直徑區域均勻度變化小於 ±1%。照明程度和模式可透過光源 EVM GUI 調整。

使用指南: PDF | HTML
支援軟體

OPTISIM — 支援 TI 光學感測器的光學光線追蹤模擬工具

OptiSim 是一款 Web 架構光學射線追蹤模擬工具,支援所有 TI 環境光和色彩感測器。此模擬器可讓使用者匯入現有光學機械設計,並評估關鍵感測器性能指標,例如角度反應及視野。此工具支援複雜的光學堆疊配置,具有多層、可變孔徑尺寸、覆蓋玻璃和可自訂折射率的光管。OptiSim 讓使用者可為每層定義這些參數,然後模擬系統反應,使其成為在設計原型之前評估性能的實用工具。
使用指南: PDF | HTML
參考設計

TIDA-01069 — 使用 PIR 感測器避免誤觸發的進階動作偵測器參考設計

此參考設計是基於雙 PIR 感測器的進階動作偵測器類比前端,可避免誤觸發並支援機器學習。此設計採用標準 BoosterPack™ 接腳配置,使用德州儀器低功耗元件,並可透過單顆 AAA 鹼性電池芯供電運作。
 
PIR_MOTION GUI 能透過多種圖表,加速從參考設計進行資料擷取並進行視覺化呈現,同時允許控制特定參數。該介面能即時顯示 PIR 感測器資料、連續小波轉換 (CWT) 結果,以及濕度、溫度與光線感測器資料。
Design guide: PDF
電路圖: PDF
封裝 針腳 CAD 符號、佔位空間與 3D 模型
USON (DNP) 6 Ultra Librarian

訂購與品質

內含資訊:
  • RoHS
  • REACH
  • 產品標記
  • 鉛塗層/球物料
  • MSL 等級/回焊峰值
  • MTBF/FIT 估算值
  • 材料內容
  • 認證摘要
  • 進行中持續性的可靠性監測
內含資訊:
  • 晶圓廠位置
  • 組裝地點

建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片