제품 상세 정보

Vrwm (V) 33 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 34.4 Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
Vrwm (V) 33 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 34.4 Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
VSON (DRB) 8 9 mm² 3 x 3
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

다운로드 스크립트와 함께 비디오 보기 비디오

기술 자료

star =TI에서 선정한 이 제품의 인기 문서
검색된 결과가 없습니다. 검색어를 지우고 다시 시도하세요.
15개 모두 보기
상위 문서 유형 직함 형식 옵션 날짜
* Data sheet TVS3301 33-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. B) PDF | HTML 2022/09/01
Application note Designing EMC-Compliant, High-Accuracy PLC Analog Input Modules (0-10V / 4-20mA) with ADS125H18 PDF | HTML 2026/07/06
Circuit design Output Overvoltage Protection Circuit for Voltage DACs With an External Feedback Pin PDF | HTML 2025/07/29
Circuit design Output Overvoltage Protection Circuit for Voltage DACs Without an External Feedback Pin PDF | HTML 2025/06/18
Analog Design Journal 태양광 애플리케이션에서 확장 가능한 입력 바이패스 스위치로 이상적인 다이 오드 컨트롤러를 사용하는 방법 PDF | HTML 2024/06/27
Analog Design Journal 4mA~20mA 루프 전원 공급 트랜스미터 설계 PDF | HTML 2024/06/26
Application note ESD Packaging and Layout Guide (Rev. B) PDF | HTML 2022/08/18
Functional safety information TVS3301 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA PDF | HTML 2021/09/27
Application brief 16-Bit 8-Channel PLC Analog Input Module with High Voltage (±150 V) Common Mode 2020/04/27
Application brief Protecting I/O modules from surge events 2019/02/04
Application brief TVS Surge Rating: Power vs. Current 2018/11/12
White paper Demystifying surge protection 2018/11/06
User guide Flat Clamp TVS Evaluation Module—Adaptor Boards 2018/09/10
Application note How to select a Surge Diode 2018/08/29
Analog Design Journal Design Considerations for System-Level ESD Circuit Protection 2012/09/25

설계 및 개발

추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.

평가 보드

FLAT-CLAMP-TVS-EVM — TVSxx0x 정밀 서지 보호 다이오드 평가 모듈

평면 클램프 TVS EVM(정밀 서지 보호 다이오드 어댑터 보드 평가 모듈)은 TVSxx0x 장치 제품군의 특성, 작동 및 사용을 보여줍니다. TVSxx0x 디바이스 제품군은 양방향 및 단방향 신호 모두에 대해 서지와 같은 과도 과전압 이벤트 동안 초저 및 평면 클램핑 전압을 유지하는 정밀 클램프입니다. 이 어댑터 보드는 TVSxx00 장치의 작은 DRV 패키지 크기와 TVSxx01 장치의 작은 DRB 패키지 크기를 산업 표준 SMA 및 SMB 패키지 유형에 맞게 설계된 더 큰 풋프린트에 배치하여 사용자가 자체 시스템에서 성능을 (...)
사용 설명서: PDF
TI.com에서 구매할 수 없음
시뮬레이션 모델

TVS3301 PSpice Transient Model

SLVMCV9.ZIP (52 KB) - PSpice Model
레퍼런스 디자인

TIDA-011026 — Field transmitter platform, 4mA to 20mA 3-wire interface reference design

This reference design gives an example implementation of a 4–20mA interface for 3-wire voltage and current interface sensors. The design enables evaluation of the XTR200 alongside the current loop protector TPS2661. The XTR200 integrates the output drive circuitry for voltage and current (...)
Design guide: PDF
레퍼런스 디자인

TIDA-010982 — 필드 트랜스미터 플랫폼, 4mA~20mA 루프 전원 공급 인터페이스 레퍼런스 설계

이 레퍼런스 설계는 2선 루프 전원 공급 센서를 위한 4~20mA 인터페이스를 구현하는 예를 보여줍니다. 이 설계를 통해 1.8V 신호 체인을 이용해 저전력 애플리케이션과 유사한 환경에서 AFE881H1 및 AFE882H1을 평가할 수 있습니다. AFE881H1 및 AFE882H1은 고정밀 16비트 DAC(디지털-아날로그 컨버터)와 HART® 모뎀을 통합합니다. 이 레퍼런스 설계는 MCU(마이크로컨트롤러)에 연결할 수 있도록 핀 헤더에 SPI(직렬 주변 기기 인터페이스) 및 UART(범용 비동기 리시버-트랜스미터) 인터페이스를 (...)
Design guide: PDF
레퍼런스 디자인

TIDA-010072 — 호흡기 애플리케이션을 위한 송풍기 및 밸브 제어 레퍼런스 설계

이 레퍼런스 설계는 많은 호흡기 애플리케이션의 핵심 요구 사항인 최대 ±200kRPM/s의 모터 가속 및 감속을 지원할 수 있는 소형 시스템 설계를 제공합니다. 이 설계는 TMS320F28027F를 비롯한 다양한 오프보드 C2000 컨트롤러를 지원하여 저비용 무센서 FOC(자속 기준 제어)를 가능하게 합니다. 또한 이 설계는 조정된 라인과 배터리 전력을 모두 지원할 수 있는 넓은 입력 전압 범위(6~28V)를 지원합니다. 송풍기 및 밸브를 구동하기 위해 이 설계는 DRV8323RS 스마트 게이트 드라이버와 DRV8847 모터 (...)
Design guide: PDF
회로도: PDF
레퍼런스 디자인

TIDA-010008 — 그리드 애플리케이션의 과도 차단 기능을 위한 평면 클램프 TV 기반 레퍼런스 설계

이 레퍼런스 설계는 플랫 클램프 서지 보호, ESD 장치, eFuse 또는 부하 스위치를 사용하여 과전압, 과부하 및 과도 전류(1.2/50µs, 42Ω)로부터 여러 그리드 애플리케이션에서 사용되는 AC 또는 DC 아날로그 입력, DC 아날로그 출력, AC 또는 DC 이진 입력, 고압측 또는 저압측 드라이버가 있는 디지털 출력, LCD 바이어스 공급, USB 인터페이스(전원 및 데이터) 및 24, 12 또는 5V 입력 온보드 전원 공급 장치를 보호하기 위한 다양한 접근 방법을 제공합니다. 이 설계는 진단을 위해 온도, 습도, (...)
Design guide: PDF
회로도: PDF
레퍼런스 디자인

TIDA-010044 — 고장 보호 및 진단을 지원하는 NAMUR PLC 디지털 입력 레퍼런스 설계

NAMUR 근접 센서는 최대 에너지에 대한 특별한 요구 사항을 센서를 사용하여 충족시키는 산업용 제어 분야에서 널리 사용됩니다. 이는 다시 정확도 및 신뢰성과 관련하여 이러한 센서와 인터페이싱하도록 설계된 PLC 디지털 입력에 대한 특별한 요구 사항에 영향을 줍니다. 이 레퍼런스 설계는 NAMUR 센서와 호환되는 디지털 입력의 완전한 프론트 엔드입니다. 이 설계는 작은 풋프린트로 이중화, 오류 보호 및 광범위한 진단 기능을 통해 신뢰성을 달성하는 방법을 보여줍니다.
Design guide: PDF
회로도: PDF
패키지 CAD 기호, 풋프린트 및 3D 모델
VSON (DRB) 8 Ultra Librarian

주문 및 품질

포함된 정보:
  • RoHS
  • REACH
  • 디바이스 마킹
  • 납 마감/볼 재질
  • MSL 등급/피크 리플로우
  • MTBF/FIT 예측
  • 물질 성분
  • 인증 요약
  • 지속적인 신뢰성 모니터링
포함된 정보:
  • 팹 위치
  • 조립 위치

권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.

지원 및 교육

TI 엔지니어의 기술 지원을 받을 수 있는 TI E2E™ 포럼

콘텐츠는 TI 및 커뮤니티 기고자에 의해 "있는 그대로" 제공되며 TI의 사양으로 간주되지 않습니다. 사용 약관을 참조하십시오.

품질, 패키징, TI에서 주문하는 데 대한 질문이 있다면 TI 지원을 방문하세요. ​​​​​​​​​​​​​​

동영상