TVS2200
- Protection against ±1 kV, 42 Ω IEC 61000-4-5 surge test for industrial signal lines
- Maximum clamping voltage of 28.4 V at 40 A of 8/20 µs surge current
- Standoff voltage: 22 V
- Tiny 4 mm 2 footprint
- Survives over 5,000 repetitive strikes of 35 A 8/20 µs surge current at 125°C
- Robust surge protection:
- IEC 61000-4-5 (8/20 µs): 40 A
- IEC 61643-321 (10/1000 µs): 5 A
- Low leakage current:
- 3.5 nA typical at 27°C
- 25 nA typical at 85°C
- Low capacitance: 105 pF
- Integrated level 4 IEC 61000-4-2 ESD protection
The TVS2200 robustly shunts up to 40 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes. The device offers a solution to the common industrial signal line EMC requirement to survive up to ±1 kV IEC 61000-4-5 open circuit voltage coupled through a 42 Ω impedance.
The TVS2200 uses a unique feedback mechanism for precise flat clamping during a fault, allowing system exposure below 30 V. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness.
In addition, the TVS2200 is available in a small 2 mm × 2 mm SON footprint which is designed for space constrained applications, offering a 70 percent reduction in size compared to industry standard SMA and SMB packages. The extremely low device leakage and capacitance causes a minimal effect on the protected line. For robust protection over the lifetime of the product, TI tests the TVS2200 against 5,000 repetitive surge strikes at high temperature with no shift in device performance.
The TVS2200 is part of TIs Flat-Clamp family of surge devices. For more information on the other devices in the family, see the Device Comparison Table.
기술 자료
| 상위 문서 | 유형 | 직함 | 형식 옵션 | 최신 영어 버전 다운로드 | 날짜 |
|---|---|---|---|---|---|
| * | 데이터 시트 | TVS2200 22-V Flat-Clamp Surge Protection Device datasheet (Rev. C) | PDF | HTML | 2023. 8. 14 | |
| 애플리케이션 노트 | ESD and Surge Protection for USB Interfaces (Rev. B) | PDF | HTML | 2024. 1. 11 | ||
| 애플리케이션 노트 | ESD Packaging and Layout Guide (Rev. B) | PDF | HTML | 2022. 8. 18 | ||
| 사용 설명서 | Generic ESD Evaluation Module User's Guide (Rev. A) | PDF | HTML | 2021. 9. 27 | ||
| Application brief | Protecting I/O modules from surge events | 2019. 2. 4 | |||
| Application brief | TVS Surge Rating: Power vs. Current | 2018. 11. 12 | |||
| 백서 | Demystifying surge protection | 2018. 11. 6 | |||
| 사용 설명서 | Flat Clamp TVS Evaluation Module—Adaptor Boards | 2018. 9. 10 | |||
| 애플리케이션 노트 | How to select a Surge Diode | 2018. 8. 29 | |||
| Application brief | Flat-Clamp TVS Layout in SMA/SMB Footprints | 2018. 4. 3 | |||
| 애플리케이션 노트 | TVS Surge Protection in High-Temperature Environments | 2018. 3. 23 | |||
| 백서 | Flat-Clamp surge protection technology for efficient system protection | 2018. 1. 15 |
설계 및 개발
추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.
FLAT-CLAMP-TVS-EVM — TVSxx0x 정밀 서지 보호 다이오드 평가 모듈
TIDA-010008 — 그리드 애플리케이션의 과도 차단 기능을 위한 평면 클램프 TV 기반 레퍼런스 설계
TIDA-050047 — 2-4 셀 배터리용 통합 USB Type-C® USB Power Delivery 및 충전 레퍼런스 디자인
이 레퍼런스 설계는 외부 FET 없이도 5A에서 최대 20V까지 충전 기능을 지원하기 때문에 훨씬 더 작은 솔루션 크기를 구현하고 총 BOM 비용을 절감할 수 있습니다. TPS25750 PD(Power Delivery) 컨트롤러가 BQ25798 배터리 충전기 IC에 대한 I2C 통신을 처리하기 때문에 마이크로프로세서도 필요 없습니다. 이 I2C 기능과 TPS25750 웹 기반 GUI는 펌웨어 개발 프로세스를 획기적으로 간소화해줍니다.
| 패키지 | 핀 | CAD 기호, 풋프린트 및 3D 모델 |
|---|---|---|
| WSON (DRV) | 6 | Ultra Librarian |
주문 및 품질
권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.