제품 상세 정보

Function General-purpose timer Iq (typ) (mA) 2 Rating Catalog Operating temperature range (°C) -40 to 105
Function General-purpose timer Iq (typ) (mA) 2 Rating Catalog Operating temperature range (°C) -40 to 105
SOIC (D) 8 29.4 mm² (4.9 mm × 6 mm) PDIP (P) 8 92.5083 mm² (9.81 mm × 9.43 mm)
  • Timing from microseconds to hours
  • Astable or monostable operation
  • Adjustable duty cycle
  • TTL-compatible output can sink or source up to 200mA
  • On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
  • Timing from microseconds to hours
  • Astable or monostable operation
  • Adjustable duty cycle
  • TTL-compatible output can sink or source up to 200mA
  • On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.

The Nx555 and Sx555 devices are precision timing circuits capable of producing accurate time delays or oscillation. In time-delay or monostable operating modes, the timed interval is controlled by a single external resistor and capacitor network. In the astable mode of operation, the frequency and duty cycle are controlled independently with two external resistors and a single external capacitor.

Each timer has a trigger level equal to approximately one-third of the supply voltage and a threshold level equal to approximately two-thirds of the supply voltage. These levels can be altered by use of the control voltage pin (CONT). When the trigger input (TRIG) is less than the trigger level, the flip-flop is set and the output goes high. If TRIG is greater than the trigger level and the threshold input (THRES) is greater than the threshold level, the flip-flop is reset and the output is low. The reset input (RESET) overrides all other inputs and is used to initiate a new timing cycle. If RESET is low, the flip-flop is reset and the output is low. Whenever the output is low, a low-impedance path is provided between the discharge pin (DISCH) and the ground pin (GND). Tie all unused inputs to an appropriate logic level to prevent false triggering

The output circuit is capable of sinking or sourcing current up to 200mA. Operation is specified for supplies of 5V to 15V. With a 5V supply, output levels are compatible with TTL inputs.

The Nx555 and Sx555 devices are precision timing circuits capable of producing accurate time delays or oscillation. In time-delay or monostable operating modes, the timed interval is controlled by a single external resistor and capacitor network. In the astable mode of operation, the frequency and duty cycle are controlled independently with two external resistors and a single external capacitor.

Each timer has a trigger level equal to approximately one-third of the supply voltage and a threshold level equal to approximately two-thirds of the supply voltage. These levels can be altered by use of the control voltage pin (CONT). When the trigger input (TRIG) is less than the trigger level, the flip-flop is set and the output goes high. If TRIG is greater than the trigger level and the threshold input (THRES) is greater than the threshold level, the flip-flop is reset and the output is low. The reset input (RESET) overrides all other inputs and is used to initiate a new timing cycle. If RESET is low, the flip-flop is reset and the output is low. Whenever the output is low, a low-impedance path is provided between the discharge pin (DISCH) and the ground pin (GND). Tie all unused inputs to an appropriate logic level to prevent false triggering

The output circuit is capable of sinking or sourcing current up to 200mA. Operation is specified for supplies of 5V to 15V. With a 5V supply, output levels are compatible with TTL inputs.

다운로드 스크립트와 함께 비디오 보기 비디오

기술 자료

검색된 결과가 없습니다. 검색어를 지우고 다시 시도하세요.
4개 모두 보기
상위 문서 유형 직함 형식 옵션 최신 영어 버전 다운로드 날짜
* 데이터 시트 xx555 Precision Timers datasheet (Rev. K) PDF | HTML 2026. 3. 4
애플리케이션 노트 Considering TI Smart DACs As an Alternative to 555 Timers PDF | HTML 2021. 9. 2
설계 가이드 AC-Coupled RS-485 Design Guide 2016. 6. 15
설계 가이드 Automatic Direction Control RS-485 Design Guide 2016. 6. 2

설계 및 개발

추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.

레퍼런스 디자인

TIDA-01090 — RS-485 자동 방향 제어 레퍼런스 디자인

TIDA-01090 레퍼런스 설계에서는 추가 드라이버 활성화/리시버 활성화 컨트롤 없이도 RS-485 버스를 통한 반이중 통신을 지원합니다.  이 설계를 사용하면 MCU(로컬 마이크로컨트롤러) 또는 UART(범용 비동기 리시버/트랜스미터)에서 데이터가 전송될 때 각 노드에 사용되는 트랜시버가 자동으로 전송 모드로 전환된 다음 데이터 프레임이 완료되면 다시 수신 모드로 전환할 수 있습니다.
지원되는 제품 및 하드웨어
레퍼런스 디자인

TIDA-01365 — 양방향 RS-485 팬 아웃 허브 레퍼런스 디자인

양방향 RS-485 팬아웃 허브 레퍼런스 설계(TIDA-01365)는 1:N 및 N:1 RS-485 신호가 모든 버스 토폴로지에서 안팎으로 집계되는 RS-485 팬아웃 허브 설계를 문서화 및 테스트합니다. 또한 이 설계는 마이크로컨트롤러의 핀 수를 줄이기 위한 자동 방향 제어와 산업용 애플리케이션에서 흔히 볼 수 있는 24V DC 레일을 사용하는 DC-DC 컨버터가 특징입니다.
지원되는 제품 및 하드웨어
패키지 CAD 기호, 풋프린트 및 3D 모델
SOIC (D) 8 Ultra Librarian
PDIP (P) 8 Ultra Librarian

주문 및 품질

권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.

지원 및 교육

TI 엔지니어의 기술 지원을 받을 수 있는 TI E2E™ 포럼

콘텐츠는 TI 및 커뮤니티 기고자에 의해 "있는 그대로" 제공되며 TI의 사양으로 간주되지 않습니다. 사용 약관을 참조하십시오.

품질, 패키징, TI에서 주문하는 데 대한 질문이 있다면 TI 지원을 방문하세요. ​​​​​​​​​​​​​​

동영상