The TMP117 is a high-precision digital
temperature sensor. It is designed to meet ASTM E1112 and ISO 80601 requirements for
electronic patient thermometers. The TMP117 provides a 16-bit temperature result
with a resolution of 0.0078 °C and an accuracy of up to ±0.1 °C across the
temperature range of –20 °C to 50 °C with no calibration. The TMP117 has in
interface that is I2C- and SMBus™-compatible, programmable alert
functionality, and the device can support up to four devices on a single bus.
Integrated EEPROM is included for device programming with an additional 48-bits
memory available for general use.
The low power consumption of the
TMP117 minimizes the impact of self-heating on measurement accuracy. The TMP117
operates from 1.7 V to 5.5 V and typically consumes 3.5 µA.
For non-medical applications, the
TMP117 can serve as a single chip digital alternative to a Platinum RTD. The TMP117
has an accuracy comparable to a Class AA RTD, while only using a fraction of the
power of the power typically needed for a PT100 RTD. The TMP117 simplifies the
design effort by removing many of the complexities of RTDs such as precision
references, matched traces, complicated algorithms, and calibration.
The TMP117 units are 100% tested on a
production setup that is NIST traceable and verified with equipment that is
calibrated to ISO/IEC 17025 accredited standards.
The TMP117 is a high-precision digital
temperature sensor. It is designed to meet ASTM E1112 and ISO 80601 requirements for
electronic patient thermometers. The TMP117 provides a 16-bit temperature result
with a resolution of 0.0078 °C and an accuracy of up to ±0.1 °C across the
temperature range of –20 °C to 50 °C with no calibration. The TMP117 has in
interface that is I2C- and SMBus™-compatible, programmable alert
functionality, and the device can support up to four devices on a single bus.
Integrated EEPROM is included for device programming with an additional 48-bits
memory available for general use.
The low power consumption of the
TMP117 minimizes the impact of self-heating on measurement accuracy. The TMP117
operates from 1.7 V to 5.5 V and typically consumes 3.5 µA.
For non-medical applications, the
TMP117 can serve as a single chip digital alternative to a Platinum RTD. The TMP117
has an accuracy comparable to a Class AA RTD, while only using a fraction of the
power of the power typically needed for a PT100 RTD. The TMP117 simplifies the
design effort by removing many of the complexities of RTDs such as precision
references, matched traces, complicated algorithms, and calibration.
The TMP117 units are 100% tested on a
production setup that is NIST traceable and verified with equipment that is
calibrated to ISO/IEC 17025 accredited standards.