The LMG365xR070 GaN FET with integrated driver and protection is targeted at
switch-mode power converters and enables designers to achieve new levels of power
density and efficiency.
Adjustable gate driver strength allows
the control of turn-on and maximum turn-off slew rates independently, which can be
used to actively control EMI and optimize switching performance. Turn on slew rate
varies from 10V/ns to 100V/ns, while the turn off slew rate can be
limited from 10V/ns to a maximum based on the magnitude of load current. Protection
features include under-voltage lockout (UVLO), cycle-by-cycle overcurrent limit, and
short-circuit and overtemperature protection. The LMG3651R070 provides a 5V LDO output on LDO5V pin that powers external
digital isolators. The LMG3656R070 includes the
zero-voltage detection (ZVD) feature which provides a pulse output from the ZVD pin
when zero-voltage switching is realized. The LMG3657R070 includes the zero-current detection (ZCD) feature that sets
the ZCD pin high when the drain-to-source current is negative and transitions to low
upon detecting the zero-crossing point.
The LMG365xR070 GaN FET with integrated driver and protection is targeted at
switch-mode power converters and enables designers to achieve new levels of power
density and efficiency.
Adjustable gate driver strength allows
the control of turn-on and maximum turn-off slew rates independently, which can be
used to actively control EMI and optimize switching performance. Turn on slew rate
varies from 10V/ns to 100V/ns, while the turn off slew rate can be
limited from 10V/ns to a maximum based on the magnitude of load current. Protection
features include under-voltage lockout (UVLO), cycle-by-cycle overcurrent limit, and
short-circuit and overtemperature protection. The LMG3651R070 provides a 5V LDO output on LDO5V pin that powers external
digital isolators. The LMG3656R070 includes the
zero-voltage detection (ZVD) feature which provides a pulse output from the ZVD pin
when zero-voltage switching is realized. The LMG3657R070 includes the zero-current detection (ZCD) feature that sets
the ZCD pin high when the drain-to-source current is negative and transitions to low
upon detecting the zero-crossing point.