NEU

INA951-SEP

VORSCHAU

Raumfahrttaugliches Produkt, Strommessverstärker, -4 V bis 80 V, 1,3 MHz

Produktdetails

Product type Analog output Common-mode voltage (max) (V) 80 Common-mode voltage (min) (V) -4 Input offset (±) (max) (µV) 150 Input offset drift (±) (typ) (µV/°C) 0.05 Features High frequency Rating Space Voltage gain (V/V) 20 CMRR (min) (dB) 140 Bandwidth (kHz) 1300 Supply voltage (max) (V) 10 Supply voltage (min) (V) 2.7 Iq (max) (mA) 2.25 Number of channels 1 Comparators (#) 0 Gain error (%) 0.15 Slew rate (V/µs) 2.5 Operating temperature range (°C) -55 to 125
Product type Analog output Common-mode voltage (max) (V) 80 Common-mode voltage (min) (V) -4 Input offset (±) (max) (µV) 150 Input offset drift (±) (typ) (µV/°C) 0.05 Features High frequency Rating Space Voltage gain (V/V) 20 CMRR (min) (dB) 140 Bandwidth (kHz) 1300 Supply voltage (max) (V) 10 Supply voltage (min) (V) 2.7 Iq (max) (mA) 2.25 Number of channels 1 Comparators (#) 0 Gain error (%) 0.15 Slew rate (V/µs) 2.5 Operating temperature range (°C) -55 to 125
SOT-23 (DBV) 5 8.12 mm² 2.9 x 2.8
  • VID In Progress
  • Radiation - Total Ionizing Dose (TID):
    • TID performance assurance up to 30krad(Si)
    • Radiation Lot Acceptance Testing (RLAT) for every wafer lot up to 30krad(Si)
  • Radiation - Single-Event Effects (SEE):
    • Single Event Latch-Up (SEL) immune up to 43MeV-cm2 /mg at 125°C
    • Single Event Transient (SET) characterized up to LET = 47.5MeV-cm2 /mg
  • Supports defense, aerospace, and medical applications
    • Operating temperature from –55°C to +125°C
    • Controlled baseline
    • Au bondwire and NiPdAu lead finish
    • Outgassing test performed per ASTM E595
    • One fabrication, assembly, and test site
    • Extended product life cycle
    • Product traceability
  • Wide common-mode voltage:
    • Operational voltage: −4V to +80V
    • Survival voltage: −20V to +85V
  • Excellent CMRR:
    • 160dB DC-CMRR
    • 85dB AC-CMRR at 50kHz
  • Accuracy:
    • Gain:
      • Gain error: ±0.15% (maximum)
      • Gain drift: ±10ppm/ °C (maximum)
    • Offset:
      • Offset voltage: ±30µV (typical)
      • Offset drift: ±0.05µV/ °C (typical)
  • Available gain:
    • INA951-SEPA1, : 20V/V
  • High bandwidth: 1.3MHz
  • Slew rate: 2.5V/µs
  • Quiescent current: 1.5mA
  • VID In Progress
  • Radiation - Total Ionizing Dose (TID):
    • TID performance assurance up to 30krad(Si)
    • Radiation Lot Acceptance Testing (RLAT) for every wafer lot up to 30krad(Si)
  • Radiation - Single-Event Effects (SEE):
    • Single Event Latch-Up (SEL) immune up to 43MeV-cm2 /mg at 125°C
    • Single Event Transient (SET) characterized up to LET = 47.5MeV-cm2 /mg
  • Supports defense, aerospace, and medical applications
    • Operating temperature from –55°C to +125°C
    • Controlled baseline
    • Au bondwire and NiPdAu lead finish
    • Outgassing test performed per ASTM E595
    • One fabrication, assembly, and test site
    • Extended product life cycle
    • Product traceability
  • Wide common-mode voltage:
    • Operational voltage: −4V to +80V
    • Survival voltage: −20V to +85V
  • Excellent CMRR:
    • 160dB DC-CMRR
    • 85dB AC-CMRR at 50kHz
  • Accuracy:
    • Gain:
      • Gain error: ±0.15% (maximum)
      • Gain drift: ±10ppm/ °C (maximum)
    • Offset:
      • Offset voltage: ±30µV (typical)
      • Offset drift: ±0.05µV/ °C (typical)
  • Available gain:
    • INA951-SEPA1, : 20V/V
  • High bandwidth: 1.3MHz
  • Slew rate: 2.5V/µs
  • Quiescent current: 1.5mA

The INA951-SEP is a current sense amplifier that can measure voltage drops across shunt resistors over a wide common-mode range from –4V to 80V. The negative common-mode voltage allows the device to operate below ground, thus accommodating precise measurement of recirculating currents in half-bridge applications. The combination of a low offset voltage, small gain error and high DC CMRR enables highly accurate current measurement. The INA951-SEP is not only designed for DC current measurement, but also for high-speed applications (ex. Fast over-current protection) with a high bandwidth of 1.3MHz and an 85dB AC CMRR (at 50kHz).

The INA951-SEP operates from a single 2.7V to 10V supply, drawing 1.5mA of supply current. The INA951-SEP is available with a gain option of 20V/V.

The INA951-SEP is specified over an operating temperature range of −40°C to +125°C and is offered in a space-saving SOT-23 package.

The INA951-SEP is a current sense amplifier that can measure voltage drops across shunt resistors over a wide common-mode range from –4V to 80V. The negative common-mode voltage allows the device to operate below ground, thus accommodating precise measurement of recirculating currents in half-bridge applications. The combination of a low offset voltage, small gain error and high DC CMRR enables highly accurate current measurement. The INA951-SEP is not only designed for DC current measurement, but also for high-speed applications (ex. Fast over-current protection) with a high bandwidth of 1.3MHz and an 85dB AC CMRR (at 50kHz).

The INA951-SEP operates from a single 2.7V to 10V supply, drawing 1.5mA of supply current. The INA951-SEP is available with a gain option of 20V/V.

The INA951-SEP is specified over an operating temperature range of −40°C to +125°C and is offered in a space-saving SOT-23 package.

Herunterladen Video mit Transkript ansehen Video

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 1
Top-Dokumentation Typ Titel Format-Optionen Datum
* Data sheet INA951-SEP –4V to 80V, 1.3MHz, Current Sense Amplifier datasheet PDF | HTML 13 Feb 2026

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

DIP-ADAPTER-EVM — Evaluierungsmodul für DIP-Adapter

Schnelleres Entwickeln von Operationsverstärker-Prototypen und Testen derselben mit dem DIP-Adapter-EVM, welches eine schnelle, einfache und preiswerte Möglichkeit zum Verbinden mit kleinen, oberflächenmontierbaren ICs über eine Schnittstelle bietet. Sie können jeden unterstützten (...)

Benutzerhandbuch: PDF
Berechnungstool

ANALOG-ENGINEER-CALC PC software analog engineer's calculator

The analog engineer’s calculator is designed to speed up many of the repetitive calculations that analog circuit design engineers use on a regular basis. This PC-based tool provides a graphical interface with a list of various common calculations ranging from setting operational-amplifier (...)

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Designtool

CIRCUIT060035 — Bidirektionale Strommessung mit einem Fensterkomparatorschaltkreis

Diese bidirektionale Strommesslösung verwendet einen Strommessverstärker und einen Hochgeschwindigkeits-Doppelkomparator mit einem Gleichtaktbereich am Rail-to-Rail-Eingang, um Überstrom-Alarmsignale (OC) an den Komparatorausgängen (OUTA und OUTB) zu erzeugen, wenn der Eingangsstrom (IG1) über (...)
Designtool

CIRCUIT060037 — Präziser Überstrom-Haltespeicher-Schaltkreis

Diese High-Side-Strommesslösung verwendet einen Strommessverstärker, einen Komparator mit integrierter Referenz und einen P-Kanal-MOSFET, um einen Überstrom-Latch-Schaltkreis zu erschaffen. Wenn ein Laststrom erkannt wird, welcher größer ist als 200 mA, trennt der Schaltkreis das System von seiner (...)
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese Design- und Simulationssuite mit vollem Funktionsumfang verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)
Simulationstool

TINA-TI — SPICE-basiertes analoges Simulationsprogramm

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
Benutzerhandbuch: PDF
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
SOT-23 (DBV) 5 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos