SLAU962A December 2025 – June 2026 MSPM33C321A , MSPM33C321A-Q1
Supported bit rates are up to the input clock divided by 2. The input clock selection depends on the specific device; refer to the device data sheet and Clock Frequency Support section.
SPI Clock is the output after clock division performed according to ratio selected by the CLKDIV register.
SPI clock = Selected input clock / (1 + CLKDIV)
SPI Sampling Clock (SCLK) is the output after dividing the SPI Clock by the Pre-scalar value.
SCLK= SPI Clock / ((1 + SCR )*2)
If the factor of two (*2) is set by CLKDIV the input clock must be at least 2 times faster than SPI clock.