ZHCSIP9A July 2018 – September 2018 DLP230KP
PRODUCTION DATA.
Micromirror array temperature cannot be measured directly, therefore it must be computed analytically from measurement points on the outside of the package, the package thermal resistance, the electrical power, and the illumination heat load. The relationship between array temperature and the reference ceramic temperature (thermal test point TP1 in Figure 18) is provided by the following equations:
TARRAY = TCERAMIC + (QARRAY × RARRAY–TO–CERAMIC)
QARRAY = QELECTRICAL + QILLUMINATION
QILLUMINATION = (CL2W × SL)
where
where
Electrical power dissipation of the DMD is variable and depends on the voltages, data rates, and operating frequencies. Nominal electrical power dissipation to use when calculating array temperature is 0.17 W. Absorbed optical power from the illumination source is variable and depends on the operating state of the micromirrors and the intensity of the light source. Equations shown above are valid for a 1-chip DMD system with total projection efficiency through the projection lens from DMD to the screen of 87%.
The conversion constant CL2W is based on the DMD micromirror array characteristics. It assumes a spectral efficiency of 300 lm/W for the projected light and illumination distribution of 83.7% on the DMD active array, and 16.3% on the DMD array border and window aperture. The conversion constant is calculated to be 0.00266 W/lm.
Sample calculations for typical projection application:
TCERAMIC = 55°C (measured)
SL = 200 lm (measured)
QELECTRICAL = 0.17 W
CL2W = 0.00266 W/lm
QARRAY = 0.17 W + (0.00266 W/lm × 200 lm) = 0.702 W
TARRAY = 55°C + (0.702 W × 9°C/W) = 61.32°C