7 |
TS_EN |
R/W |
1b1 |
TS Function Enable
1b0 = TS function disabled (Only charge control is disabled. TS monitoring is enabled)
1b1 = TS function enabled
|
6 |
TS_CONTROL_MODE |
R/W |
1b0 |
TS Function Control Mode
1b0 = Custom (JEITA)
1b1 = Disable charging on HOT/COLD Only
|
5 |
VRH_THRESH |
R/W |
1b0 |
Recharge Voltage Threshold
1b0 = 140mV
1b1 = 200mV
|
4 |
WATCHDOG_DISABLE |
R/W |
1b0 |
Watchdog Timer Disable
1b0 = Watchdog timer enabled
1b1 = Watchdog timer disabled
|
3 |
2XTMR_EN |
R/W |
1b0 |
Enable 2X Safety Timer
1b0 = The timer is not slowed at any time
1b1 = The timer is slowed by 2x when in any control other than CC or CV
|
2-1 |
SAFETY_TIMER_LIMIT_1:0 |
R/W |
2b01 |
Charger Safety Timer
2b00 = 3 Hr Fast Charge
2b01 = 6 Hr Fast Charge
2b10 = 12 Hr Fast Charge
2b11 = Disabled
|
0 |
RESERVED |
R/W |
1b0 |
Reserved |