TMAG5213
- Z-axis Hall-effect bipolar latch
- 30kHz magnetic sampling frequency
- Multiple sensitivity options (BOP / BRP)
- ±2.7mT (AD, see Device Nomenclature)
- ±6mT (AG, see Device Nomenclature)
- Supports a wide voltage range
- 2.5V to 28V
- No external regulator required
- Wide operating temperature range
- TA = –40°C to +125°C
- Open-drain output (30mA sink)
- 35µs power-on time
- Industry standard package and footprint
- Surface mount 3-pin SOT-23 (DBZ)
- 2.92mm × 2.37mm
- Through-hole 3-pin TO-92 (LPG)
- 4.00mm × 1.52mm
- Surface mount 3-pin SOT-23 (DBZ)
- Protection features:
- Output short-circuit protection
- Output current limitation
The TMAG5213 is a low-cost, chopper-stabilized Hall-effect sensor with excellent sensitivity stability over temperature and integrated protection features.
The magnetic field is indicated through a digital bipolar latch output. When the applied magnetic flux density crosses the operating point (BOP) threshold, the device outputs a low voltage. The output stays low until the flux density crosses the release point (BRP), at which point the device output gets pulled high. This bipolar latch magnetic response allows the device output to be sensitive to positive and negative magnetic flux through the Z-axis of the package.
The TMAG5213 has a wide operating voltage range from 2.5V to 28V and operating temperature range from –40°C to +125°C designed for a variety of industrial applications. Internal protection functions are provided for output short circuit or overcurrent, and the device has an open-drain output stage with 30mA current sink capability.
技术文档
类型 | 标题 | 下载最新的英语版本 | 日期 | |||
---|---|---|---|---|---|---|
* | 数据表 | TMAG5213 Low-Cost Hall-Effect Latch 数据表 (Rev. A) | PDF | HTML | 2024年 4月 17日 |
设计和开发
如需其他信息或资源,请点击以下任一标题进入详情页面查看(如有)。
HALL-ADAPTER-EVM — 霍尔传感器分线适配器评估模块
封装 | 引脚 | 下载 |
---|---|---|
SOT-23 (DBZ) | 3 | 查看选项 |
TO-92 (LPG) | 3 | 查看选项 |
订购和质量
- RoHS
- REACH
- 器件标识
- 引脚镀层/焊球材料
- MSL 等级/回流焊峰值温度
- MTBF/时基故障估算
- 材料成分
- 鉴定摘要
- 持续可靠性监测
- 制造厂地点
- 封装厂地点
推荐产品可能包含与 TI 此产品相关的参数、评估模块或参考设计。