over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
VS |
Supply voltage dual supply, VS = (V+) – (V–) |
|
±18 |
V |
Supply voltage single supply, VS = (V+) – (V–) |
|
36 |
|
Input signal voltage(2) |
(V–) – 0.7 |
(V+) + 0.7 |
V |
|
Input signal current(2) |
|
10 |
mA |
|
Output short-circuit(3) |
Continuous |
|
TA |
Operating Temperature |
–55 |
125 |
°C |
|
Lead temperature (soldering, 10 s) |
|
300 |
°C |
Tstg |
Storage Temperature |
–55 |
125 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) Input signal voltage is limited by internal diodes connected to power supplies. See
Input Protection.
(3) Short-circuit to VS / 2.